NEX S
9 Appendix A: Installation protocol
• Copy the installation protocol, fill it in and save it as a service record.
• For values, note the value in the result column, otherwise, a tick will suffice if the item has been performed or
considered.
WARNING! Risk of personal injury
No zone present during installation, service and cleaning.
NOTE!
If a value is outside its accepted level, or a result is incorrect or missing, fix the problem before initial
start-up and normal operation.
Unit No.:
Date:
Performed by:
Control items
Reference
Result
Notes
APPLICATION REQUIREMENTS LIMITS
Installation Area classification Zone, dust
21,22 Zone, gas 1, 2
Material MIE (>1 MJ).
DELIVERY CONTROL
Transport damage
Missing components
Maintenance access
MOUNTING
Bolts and nuts suitable for the wall mater-
ial. 1100N/2400N/4000N
Extraction arm is fitted in a horizontal po-
sition.
NEX S housing is properly grounded.
Earth continuity < 100 ohm.
EN