3
0
1
0
1
0
1
Alf Jonasson, Product Manager
This product is designed to meet the requirements of the relevant
EC directives. To maintain this status all installation, repair and
maintenance work must be carried out by qualified personnel using
only original spare parts. Contact your nearest authorised dealer or
AB Ph. Nederman & Co. for advice on technical service or if you
require spare parts.
Declaration of conformity
We, AB Ph. Nederman & Co., declare under our sole
responsibility that the Nederman product:
- FilterMax DX series 667 and its accessories
to which this declaration relates, are in conformity with
the following standards or other normative documents:
EN 286-1, EN 1127-1, EN 50281-1 following the provisions of
Directive 98/37/EC, 89/336/EEC and ATEX 94/9/EC.
AB Ph. Nederman & Co.
Sydhamnsgatan 2
S-252 28 Helsingborg Sweden
2001-02-01
R
Filtration
Operating airflow
Filterarea/filter cartridge
Filter material
Environ temperature
Process air (dry) temperature
Material description
Compressed air requirements
Compressed air consumption
Compressed air connection
Voltage supply
Protection class
Relay voltage, accessory
Working pressure
Pulse noise
Weight
Dimensions
TECHNICAL DATA
Basic filter: 99% weight filtration BIA class C
1 module: 2400 - 3600 m
3
/h (depending o load)
2 modules: 4800 - 7200 m
3
/h (depending on load)
3 modules: 7200 - 10800 m
3
/h (depending on load)
1 module: 60 m
2
2 modules: 120 m
2
3 modules: 180 m
2
Metal covered polyester
-20
°
C to +60
°
C
0
°
C to +60
°
C, not condensing
3 mm painted steel, epoxy based zinc prime and top coat
0,6 MPa (6 bar / 87 psi), water and oil free
32 N-litres / cleaning pulse, at 0,6 MPa (6 bar / 87 psi)
1/2" (R 15)
100 V, 120 V, 230 V AC, 50/60 Hz
IP 65
24 V AC, max. 60 VA
0 to -5 kPa, not overpressure
Lp Aeq, 30 s, 50 dB
1 module: 720 kg
2 modules: 1170 kg
3 modules: 1630 kg