26
0
1
• Unscrew the inspection covers on top of the inlet and
outlet. Check the seals. Clean when necessary.
• Check that there is no water in the pressure tank
(tanks), by opening the drain nipple on the right
bottom side of the tank.
• Make a complete earth control measuring
(see instructions page 13)
• Take measures against possible corrosion on
FilterMax DX.
• Check that the conductive surface layers on the filter
cartridges not are damaged (specially important if the
dust ignition energy MIE is less than 10 mJ).
SERVICE AFTER 2000 OPERATION HOURS, BUT AT LEAST
ONCE A YEAR OR WHEN REPLACING FILTER CARTRIDGES
Inspection covers
• Check that all valves in the cleaning system operate properly. Count the
number of air pulses, 6 per module, that is 6, 12 or 18 per cycle.
• Check that the relief sheets on FilterMax DX not are damaged or blocked.
• Remove dust collections from the lower part of the clean air room.
• Remove dust collections on monitoring system and pilot box.
SERVICE AFTER 1000 OPERATION HOURS,
BUT AT LEAST ONCE EVERY 6TH MONTH
REPLACING THE FILTER CARTRIDGES AT
DAMAGE OR INSUFFICIENT FILTER FUNCTION,
BUT AT LEAST AFTER 6000 OPERATION HOURS
The filter cartridges are replaceable. They should be
replaced if the outer surfaces are damaged or if the air flow
through FilterMax DX is insufficient due to saturation of the
filter cartridges despite repeated cleaning.
WARNING!
Risk of personal injury!
For FilterMax DX equipped with 2 or 3 modules
(12 or 18 filter cartridges), an approved lifting work
platform (see figure) has to be used when
exchanging the filter cartridges.
Instructions for replacing the filter cartridges,
see next page.