Series 886 Ex
EN
8
1
Product marking
Hose Reel 886 Ex is ATEX classified and marked:
II 2G Ex h IIB T60ºC…150ºC Gb
II 2D Ex h IIIC T60ºC…150ºC Db
-10ºC≤Ta≤60ºC
Nederman 19.HB07X
Part
Explanation
II:
Equipment group (non mining)
h:
The letter ”h” as specified in EN ISO 80079-36.
IIB:
Equipment of Group II is intended for use in places with an explosive gas atmosphere
other than mines susceptible to firedamp.
Equipment of Group II is subdivided according to the nature of the explosive gas
atmosphere for which it is intended.
Group II subdivisions:
• IIA, a typical gas is propane;
• IIB, a typical gas is ethylene;
• IIC, a typical gas is hydrogen.
IIIC:
Equipment of Group III is intended for use in places with an explosive dust atmosphere
other than mines susceptible to firedamp.
Equipment of Group III is subdivided according to the nature of the explosive dust
atmosphere for which it is intended.
Group III subdivisions:
• IIIA: suitable for combustible flyings;
• IIIB: suitable for combustible flyings and non-conductive dust;
• IIIC: suitable for combustible flyings, non-conductive dust and conductive dust.
T60ºC…150ºC
The maximum surface temperature in degrees Celsius.
This is set as a range since it depends on the temperature of the media used.
Gb:
Equipment protection level Gb. Same as old 2G marking.
For explosive atmospheres, caused by mixtures of air and gases, the equipment does not
contain any effective ignition sources in normal operation and expected malfunctions.
Db:
Equipment protection level Db. Same as old 3D marking.
For explosive atmospheres, caused by mixtures of air and combustible dusts, the
equipment does not contain any effective ignition sources in normal operation and
expected malfunctions.
-10ºC≤Ta≤60ºC
Ambient temperature range
Nederman 19.HB07X Certificate number. If the sign “X” is placed after the certificate number, it indicates that
the equipment is subject to specific conditions for safe use.
Special Conditions for Safe Use “X”
Only to be used with Nederman accessories (30400110, 30400210, 30400211, 30400310,
30410110, 30431310, 30431410, 30431510, 30431610, 30431710, 30431810, 30431910,
30432010). Other equipment may be connected if it has a capacitance < 100pF measured
according to EN IEC 60079-0 26.14. Or that the reel with conductive media inside the hose, has
a resistance to ground from the connected equipment of less than 1M ohm with the hose fully
unrolled from the reel.
Type of Protection constructional safety “c”
Technical documentation contains the information required to maintain the product safety.
Summary of Contents for 886 Ex Series
Page 2: ......
Page 6: ...Series 886 Ex 6 Figures 1 2 ...
Page 14: ...Series 886 Ex EN 14 ...
Page 22: ...Series 886 Ex DA 22 ...
Page 30: ...Series 886 Ex DE 30 ...
Page 38: ...Serie 886 Ex ES 38 ...
Page 52: ...Series 886 Ex FR 52 ...
Page 60: ...Series 886 Ex IT 60 ...
Page 68: ...Series 886 Ex NO 68 ...
Page 76: ...Seria 886 Ex PL 76 ...
Page 84: ...Series 886 EX SV 84 ...
Page 85: ......
Page 86: ...www nederman com ...