A lockable safety switch is recommended
for the electrical system including the fan.
Ordering Instructions
When ordering spare parts always indicate the following:
A.
Part No. and Control No. (see sign plates on the trolley and one of the rail profiles).
B.
The spare part's name and number (see list below).
C.
Quantity of parts required.
Spare parts
Recommended pressure drops and air flows
800 Pa + 45 Pa/m rail at 1000 m
3
/h (nozzle 6")
3.2 in.wg + 0.055 in.wg/ft. of track at 600 cfm (6" nozzle)
800 Pa + 30 Pa/m rail at 600 m
3
/h (nozzle 5")
3.2 in.wg + 0.037 in.wg/ft. of track of 400 cfm (5" nozzle)
Fans
Fans are not included in the basic package. For
best result, one fan per extraction unit is recom-
mended, but it is also possible to connect several
units to a central fan.
To get underpressure in the ducting system and
avoid exhaust leakage, the fan should be positio-
ned as close to the outlet from the room as pos-
sible.
Spare parts list
2
Trolley, complete
18
Horizontal hose incl. carrier units
9
Nozzle, incl. hose
and spring
19
Carrier units, set (5 pcs.)
10
Friction blocks, pair
22
End stop
11
Rubber collar
25
Mounting chain with bracket
(1 pc.)
12
Hose for nozzle
26
Connection hose
13
Vertical hose
27
Disconnection magnet
14
Electromagnetic unit
28
Wheel set for trolley
15
Anchor plate
29
Profile incl. lengthening joint
16
Adapter
30
End profile incl. lengthening joint
17
Disconnection box
31
Elastic cord and quick-couplings
29
30
28 17
19
25
27
15
9 10 11
14
12
13
22
18
26
16
31