WIM | INSTALLATION GUIDE
Plate Conversion Modes
8/20
5
PLATE CONVERSION MODES
The plate conversion mode is selected using the 4 switches located on the device
rear panel.
Plate Conversion Mode
1
2
3
4
Mode
Hex
Wiegand 26-bit SHA-1 (see chapter 5.1)
ON
ON
ON
ON
0F
Wiegand 64-bit (see chapter 5.2)
OFF
ON
ON
ON
0E
Magstripe ISO7811 track 1 (see chapter 5.4)
ON
OFF OFF
ON
09
Magstripe ISO7811 track 2 (see chapter 5.5)
OFF OFF OFF
ON
08
Barcode code39 emulation (see chapter 5.6)
ON
OFF OFF OFF
01
Wiegand match-list mode (see chapter 5.3)
OFF OFF OFF OFF
00
Wiegand match-list-XL mode (see chapter 5.3)
OFF OFF
ON
OFF
04
5.1
WIEGAND 26-BIT (SHA-1)
In this mode, every received license plate message is converted to a Wiegand 26-bit
output message using the SHA-1 security hashing algorithm.
Wiegand 26-bit SHA-1 conversion procedure:
1
Receive license plate message
hk 55 evb
2
Turn into upper case
HK 55 EVB
3
Remove spaces
HK55EVB
4
Calculate SHA-1 digest
A44F633C 8A6D1581
50CCEB3E F83D9DE0
BA80CF15
5
Truncate. Keep least significant 24-bits
A80CF15
6
Add parity bits according to Wiegand 26-bit format
The WIM_Calc software is available to calculate Wiegand output numbers for
specific license plates.
Figure 4: WIM_Calc software screenshot
5.2
WIEGAND 64-BIT
In this mode, every received license plate message is converted to a Wiegand 64-bit
Note
In Wiegand 26-bit (SHA-1)
mode it is not required to
use the LAN connection.
Note
In Wiegand 64-bit mode it
is not required to use the
LAN connection.