VP1006-200PM-00 OEM ISO Reader
Manual version 2.6 / Page
3
2
Description and functioning
A VP1006 has 6 inputs used for reading e.g. sensors or switches.
There are also 6 outputs available to activate e.g. lights, motors, valves or relays.
The VP1006 can read tags FDX/HDX 134.2 kHz.
The VP1006 must be connected to a computer and can communicate by a CAN, RS485 or RS232
protocol. The connected computer must give controlling commands to the VP1006 to operate inputs,
outputs and identification.
Figure : Sticker on the VP1006 with indication of the connections
Input/output 1 to 4 ( I/O 1 till I/O 4 ) can be used to control feed motors or can be used as normal
input/output. Output/input 5 and 6 ( I/O 5 - I/O 6 ) can only be used as output/input, not for feed motors.
Operation of the VP1006
Antenna : for reading tags, normally on
Inputs : read continuously with status change sent to the controller
Outputs : switched on or off by commands from the controller
LEDs : switched on or off by the VP1006 according to the status
Error : errors are sent to the controller
All inputs and outputs can be tested by the use of the push button and display. For operation of the
push button and display see appendix B.
3
Safety
Installation and service only by trained personnel.
Always turn off the main power when working on the electrical installation.
4
Installation
Installation consits of the following steps:
1. Mounting
2. Installation of all wiring (connections)
3. Power up
4. Set address (when more then one VP1006)
5. Set communication protocol
6. Antenna adjustment (green LED on)
7. Checking the connected equipment like lamps, motors, sensors etc.
8. Configuration in the PC
Follow this manual to complete the steps.
4.1 Mounting
See the relevant equipment manual relating to where the VP1006 is to be installed.