TRANSIT Entry Quick Reference
TRANSIT Entry Quick Installation Guide
Page 6 of 7
LED
Description
RX LEVEL
LED bar indicating the received tag signal strength. This LED bar may also indicate the
presence of radio interference. In case of interference, try switching to a different frequency.
RDIS
Read Disable LED. On while reading disabled.
IN1
Input 1 status. On when input 1 contact is closed.
TXD
Transmit serial data (RS232, RS422, USB, I/F-board).
RXD
Receive serial data (RS232, RS422, USB, I/F-board).
ID
Identification. Blinks fast when a valid transponder is identified.
STS
Status LED.
System’s heartbeat (0.8 sec on / 0.8 sec off). Indicates that the power is on and the
processor is running.
Bootloader says hello. Indicated after a restart.
Configuration menu active.
Abnormal situation.
SQ-ENA Squelch
enabled.
SQ-ACT Squelch
active.
DC-HI
Power supply voltage too high.
DC-LO
Power supply voltage too low.
DC-FAIL
Internal supply voltage failure.
T-CRIT Temperature
critically
high.
PLL UL
PLL unlocked. Try switching to a different frequency.
Table 1: LED indicators
Step 8 Frequency selection
The TRANSIT Entry reader operates in the
2.45GHz frequency band. When two or more
readers are within a range of 15 meters (50 feet),
these readers should be set on a different
operating frequency. The selected frequency has
to comply with local radio regulations.
1) Press the UP or DOWN switch once.
2) The display will show a value indicating
the currently selected frequency.
3) Lookup the display value for the actual
operating frequency is.
4) When the display is on, press the UP
switch to select a higher frequency and
press the DOWN switch for a lower
frequency.
5) The display will automatically switch off
after 5 seconds.
DISPLAY