BOOSTERS 2G
© Nedap IDEAS, P.O. Box 103, NL-7140 AC GROENLO
Page 16 of 21
4.3
16B
PROGRAM THE CONFIGURATION CARD
4.3.1
22B
USING A SUPPORTED PROGRAMMER
The software supports a few different programming devices. The NXP Pegoda, the HID OMNIKEY 5x21 and PC/SC
contactless readers from the Springcard CSB6 Family (e.g. Prox 'n' Roll PC/SC).
4.3.1.1
31B
NXP PEGODA PROGRAMMER
Connect the NXP Pegoda Mifare programmer to a USB port on your computer. USB drivers
must be installed as described in the NXP documentation.
In the ‘Programmer’ menu select the 'NXP Pegoda' and click ‘Connect’ to connect to the
programmer.
4.3.1.2
32B
HID OMNIKEY 5x21-CL PROGRAMMER
Connect the HID OMNIKEY 5x21-CL USB programmer to a USB port on your computer. USB
drivers must be installed as described in HID documentation.
In the ‘Programmer’ menu select 'HID OMNIKEY' and click ‘Connect’.
4.3.1.3
33B
SPRINGCARD CSB6
The SpringCard CSB6 and Prox 'n' Roll PC/SC share the same architecture. Install the PC/SC
drivers as described in the SpringCard documentation. Connect the CSB6 to a USB port on
your computer.
In the ‘Programmer’ menu select 'SpringCard CSB6' and click ‘Connect’.
4.3.1.4
34B
PROGRAMMING
Once the connection has been established and all configuration settings are entered, place an empty Mifare
Classic 1K or 4K card on the programmer.
To program the configuration into the Mifare card click ‘Write configuration into card’ in the ‘Programmer’
menu. The message ‘Configuration written into card’ should appear to indicate that the programming action
was successful.
3TP
4F
1
The software will warn you with the message ‘Overwrite configuration card’ if there is already a configuration on
the Mifare card. Click ‘Yes’ to proceed and overwrite the configuration on the card or click ‘No’ to abort.
4.3.1.5
35B
READ BACK
It is also possible to read back what configuration is programmed into a configuration card. Click ‘Read
configuration from card’ in the ‘Programmer’ menu.
P
The HID OMNIKEY programmer sometimes requires to remove and replace the config card before re-
accessing the card is possible.