![Nedap PowerRouter PR50SB-PR/S24 Installation Manual Download Page 49](http://html1.mh-extra.com/html/nedap/powerrouter-pr50sb-pr-s24/powerrouter-pr50sb-pr-s24_installation-manual_3851892049.webp)
PowerRouter • Back-up / Stand-alone • Installation Manual
9 Technical specifications
47
EN
i
All specifications apply at 25
o
C unless stated otherwise.
Environmental
PR50SB-PR/S24
PR37SB-PR/S24
PR30SB-PR/S24
Operating temperature range (full power)
-10
o
C to +50
o
C (derating to prevent overtemperature)
Storage temperature
-40
o
C to +70
o
C
Humidity
maximum 95%, non-condensing
Regulatory approvals and standards
CE, VDE-AR-N 4105:2011-08, EEG2012, C-Tick
Safety
EN 60950-1, EN 62109-1-2, EN 60335-2-29, EN 62040-1
Emission
EN 61000-3-2, EN 61000-3-3, EN 61000-6-3, EN 61000-3-12
Immunity
EN 61000-6-2, EN 61000-3-11
Anti-islanding protection
VDE 0126.1.1, G83/1(UK), RD1699/2011(ESP), CEI0-21 (IT), AS4777
(AUS)
(check www.PowerRouter.com for other country certifications)
Warranty
five years (optional: extension to ten years)
General
PR50SB-PR/S24
PR37SB-PR/S24
PR30SB-PR/S24
Dimensions (W x H x D)
765 x 502 x 149 mm
Protection category
indoor use (IP20)
Weight
21.5 kg
Topology
galvanically isolated transformer
Cooling
forced airflow
Summary of Contents for PowerRouter PR50SB-PR/S24
Page 1: ...Installation Manual PowerRouter Solar Battery Back up Stand alone Date 181213...
Page 9: ...PowerRouter Back up Stand alone Installation Manual Illustrations 7 19 20 21 22...
Page 10: ...Illustrations PowerRouter Back up Stand alone Installation Manual 8 23 24...
Page 50: ...9 Technical specifications PowerRouter Back up Stand alone Installation Manual 48 EN...
Page 51: ......