Specifications QXMK2. 

 

Enviromental 

 

 

 

 

 

Description  

PG27 

PG39 

FL30 

FL45 

  

Antenna Hight 

1533mm 

1670mm 

1665mm 

1665mm 

  

Antenna With 

273mm 

390mm 

322mm 

462mm 

  

Antenna Base 

104mm 

104mm 

100mm 

100mm 

  

Frame thickness 

20mm 

20mm 

70mm 

70mm 

  

Weight 

13Kg 

20Kg 

12Kg 

15Kg 

  

Material Construction 

PMMA 

PMMA 

Aluminum 

Aluminum 

  

Material Covers 

RVS Steel 

RVS Steel 

ABS HI-121, Calibre 201-15 

  

Protection Class 

IP20  

  

 

 

 

 

 

 

Description 

  

  

  

  

  

  

Min. 

Typical 

Max. 

Condition 

  

EAS Operating frequency 

7.4 MHz 

  

8.8 MHz 

  

  

Metal Detection Operating 
Frequency 

120 kHz  

125 kHz 

130 kHz 

  

  

Operational temperature 

0°C 

  

40 °C 

  

  

Storage temperature 

-10°C 

  

+70°C 

 

Relative Humidity 

20% 

  

90% 

non-condensing 

Operating Distance 

0.9m 

  

2.4m 

Between antenna, Tag dependant 

 

 

 

 

 

 

Input Requirements and electrical specifications 

 

 

 

Description 

Min. 

Typical 

Max. 

Condition 

  

Input Voltage 

90VAC 

  

264VAC 

Full Range; 50/60Hz 

Input Current 

2A  

90VAC 50Hz 

  

Line Frequency 

47 Hz 

50-60Hz 

63Hz 

  

Inrush Current @25°C 

  

  

60A 

230VAC Cold Start 

Operation Voltage 

29.1VDC 

30VDC 

30.9VDC 

  

  

Power 

15W 

  

20W 

230VAC 
50Hz 

  

 

 

 

 

 

 

Regulations 

 

 

 

 

 

Safety approvals of the Power Adapter: 

  

  

  

· cULus according to UL/CSA 60950-1 and UL1310 NEC Class 2  

  

· Japan PSE 

 

 

 

 

  

· CE Europe according to EN60950-1  

 

 

  

Telecom system approval 

  

  

  

  

· Canada IC ID according to RSS210 IC ID: 1444A-XQMK2 

  

  

 · US according to FCC Part 15 FCC ID: CGDXQMK2 

 

  

· CE according to EN 300 330 

 

 

  

In compliance with Human exposure assessment according to: 

  

  

· EN62369-1 and EN50364 

  

  

  

  

· ICNIRP Guidelines 

 

 

 

  

· IEEE C95.1 

 

 

 

  

· RSS102 

 

 

 

 

  

· ARIB STD-38 

 

 

 

  

Electromagnetic compatibility  

  

  

  

  

· EN 301 489  

  

  

  

  

· IEC 61000-6-2  

 

 

 

  

· IEC 61000-6-3 

 

 

 

  

· CISPR 22 / EN55022 

  

  

  

  

 

Summary of Contents for Dynamic Series

Page 1: ...ication conveys no license under patent or other right nor does the publisher assume Liability for any consequence of its use specifications and availability of goods mentioned in it are Subject to ch...

Page 2: ...96 EC WEEE This is in addition to the marking requirement in Article 10 3 of this Directive which requires producers to mark electrical and electronic equipment put on the market after 13 August 2005...

Page 3: ...Net and the Nedap EASi Net are registered trademarks of N V Nederlandsche Apparatenfabriek Nedap Other product names mentioned in this manual may be trademarks or registered trademarks of their respec...

Page 4: ...Page 4 of 9 Table of content 1 Introduction 5 2 System overview 6 3 Wiring diagram 7 4 FCC Declarations 8 5 Specifications XQMK2 9...

Page 5: ...buildup in four different types of components Antennas with the following types PG27 PG39 FL30 and FL45 Transmitter and Receiver units installed into the antenna s Network controller unit named NCC Po...

Page 6: ...lation guide lines o Power up the XQMK2 system o Check the functionality o Call Nedap Customer Support for quick hands on problem solution in case of unforeseen problems see Technical Support o Distan...

Page 7: ...r Rx 8018472 to the Metal detection antenna loop PG27 PG39 FL30 FL45 5 Cable for Customer counting and lighting unit PG27 PG39 Connects the XQMK2 Tx 8018464 or Rx 8018472 to the Customer Counter and l...

Page 8: ...es pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radi...

Page 9: ...0 9m 2 4m Between antenna Tag dependant Input Requirements and electrical specifications Description Min Typical Max Condition Input Voltage 90VAC 264VAC Full Range 50 60Hz Input Current 2A 90VAC 50Hz...

Reviews: