NED
XCM6040SAT2 UME-0027-03
26
4.1.4 Camera Control Commands
Table 4-1-4-1 List of Camera Control Commands
Control Item
CMD
VAL1
VAL2
VAL3
Control Description
Analog Gain
gax
0 to 20
x1.00...x11.22(1.06dB/step)
Digital Gain
gdx
0 to 511
x1...x2(x0.003906/step)
Digital Offset
odx
-15 to 15
-15...15(1DN/step at8bit)
-60...60(4DN/step at10bit)
Exposure Mode
inm
0 /1/2/3
Free Run / Ext Edge / Ext Level
/ Multi slope
Programmable Exposure
Time
int
0 to 11
61 to
1023
73.2
~
1257062.40
μs
(VAL1: Dividing, VAL2:
Counter)
Output Signal Setting 1
voa
0 /1
0
VAL1:8bit
/10bit
selection,
VAL2:0(Fixed)
Output Signal Setting 2
voc
0 /1
Linear /Log
Memory Initializing
rst
Reset to factory settings
Memory Load
rfd
Readout setup data in memory
Memory Save
sav
Store present setup data in
memory
Test Pattern
tpn
0 /1
OFF/ON
Pixel
Correction
Data
Save
wht
Store pixel correction data in
memory
Pixel Correction Setting
shc
0/1/2
0 to
1023
0:Correction
OFF
/1:Factory
white correction /2:User white
correction,
Correction
level
(10-bit)
Exposure-Readout Time
pad
0 to 50
0 - 61440
μs
Operation Status
Readout
sta
Returns the current camera
settings.
Scanning Direction
rev
0 /1
0 : Forward / 1 : Reverse
Multi-slope level setting
msl
0 to 15
0 to 15
0 to 15
Set the output level aspect of the
vertex of the multi-slope function
VAL1<=VAL2<=VAL3