NED
XCM8060SA_8040SA_6040SA
UME-0034-03
34
4.2.14 Setting Exposure Time - Readout Time
Prolongs the line period without changing the exposure time.
Format 2
CMD
□
VAL1 CR
CMD
pad
VAL 1
0 -50 (XCM8060SA: 0 - 54613
μs, XCM8040SA:0-81920μs
XCM6040SA:0-61440
μs)
<Example>
pad
□
10 CR
>OK
>pad 10
The increment of the line period depends on the exposure time setting command
“int”. For XCM8060SA, if VAL1 (in “int”)=0 and VAL1 (in “pad”)=1, the increment is
16.7nsx2x16x2=1.07
μs. If VAL1 (in “int”) = 3 and VAL1 (in “pad”)=1, the increment
is 16.7nsx2x16x(2x2x2)=4.27
μs. For XCM8040SA or XCM6040SA, change the
above 16.7ns into 25ns or 18.8ns respectively.
4.2.15 Returning the Current Camera Settings
Returns the current camera settings.
Format 1
CMD CR
CMD
sta
<Example>
sta CR
>OK
>Type=XCM8040SA
>Ver.=2.06_0x4063
>Serial=0
>check_code = 20070615
>gax 0
>gdx 0
>odx 0
>inm 0
>int 0,61
>cka 0
>voa 0,0
>voc 0
>tpn 0
>shc 1,600
>pad 0
>rev 0
>sta