4.2.11 White Pixel Correction Data Save
Save the user arbitrary white pixel correction data of analog gain in flash memory.
The data at each step of analog gain can be saved.
Format 1 CMD CR
CMD wht
<Example>
wht CR
>OK
>wht
4.2.12 Initializing Pixel Correction Data
Deletes user arbitrary pixel correction data and resets to factory settings.
All of data of analog gain reset to factory settings except for the gain setting and
offset setting of the camera setting.
When the camera is shipped out, the data of factory black pixel correction and
factory white pixel correction is stored.
It takes about one minute and 30 seconds to complete this command task after the
command is sent.
Note
:
While the command task is executed, the camera does not respond for about
1 minute. After that, OK comes back from the camera.
Do not turn off the power supply of the camera during this execution or
the camera may be damaged.
Format 1 CMD CR
CMD calibde
<Example>
calibdef CR
>OK