background image

Installation

IMPORTANT – The installation of the Baker’s Oven must comply with current local, national, 
and/or European regulations applicable to wood burning appliances.

Clearances

The clearances from the appliance to combustible materials must not be less than the 
following:- 

Rear

250 mm

Side

450 mm

If the appliance is placed in the corner of a room, the minimum clearance from the corner 
edge of the appliance to the nearest combustible surface is 250mm.

If the walls adjacent to the appliance are a non-combustible material and minimum 75mm 
thick, then the minimum clearance is 25mm.

Never store any flammable materials near the stove.

Hearth Requirements

The hearth on which the Baker’s Oven is to be placed should be constructed of non-
combustible material in accordance with Building Regulations Approved Document J (Section 
2 – Hearths). 

The hearth should extend a minimum 300mm in front of the Baker’s Oven.

Summary of Contents for NBO

Page 1: ...NECTRE WOOD STOVES Installation Operating Instructions Baker s Oven Model NBO 10 Tested to EN12815...

Page 2: ...ed technical drawing for other dimensions not listed here Specification Baker s Oven Nominal heat output 10 6 kW Total efficiency 77 3 Mean CO Emission at 13 O2 0 55 Mean flue gas temperature 274 9 C...

Page 3: ...perature NOTE the temperature gauge on the oven door is only a guide to the temperature in the oven We have found that when the gauge is reading around 100 C the internal oven temperature is more like...

Page 4: ...a chimney fire close the primary air spindle control to suffocate the fire After a prolonged period of no use the chimney and the appliance should be checked for blockages prior to lighting Maintenan...

Page 5: ...eets Over time these can burn through In such an event new ones can be sourced from your dealer and re hung inside the firebox Key Environmental Considerations To minimise the impact on the environmen...

Page 6: ...minimum clearance from the corner edge of the appliance to the nearest combustible surface is 250mm If the walls adjacent to the appliance are a non combustible material and minimum 75mm thick then t...

Page 7: ...f the chimney with a register plate and fit the flue pipe up through the plate and continue the flue until it terminates outside the chimney in accordance with Building Regulations Approved Document J...

Page 8: ...s warranty Pecan Engineering Pty Ltd assumes no responsibility for the labour costs involved in removing or replacing the stove Nor shall Pecan Engineering Pty Ltd be liable for any injury loss or dam...

Reviews: