background image

Introduction

Thank you for purchasing a Nectre Baker’s Oven. The Baker’s Oven combines a wood-
fuelled heater with an oven and cook top. The oven will cook anything from crispy bread to 
succulent roasts. The cook top takes four large saucepans and features two removable rings 
for wok-style cooking. 

Best of all, your Baker’s Oven will spread warmth throughout your kitchen and living area 
while it cooks. 

Technical Data

Please refer to attached technical drawing for other dimensions not listed here.

Specification

Baker’s Oven

Nominal heat output

10.6 kW

Total efficiency

77.3%

Mean CO Emission (at 13% O

2

)

0.55%

Mean flue gas temperature

274.9°C

Flue mass gas flow

8.483 g/s

Minimum flue pipe diameter

150mm / 6 inches

Minimum flue draft

1.0 – 1.2mm w.g.

Appliance size (W x D x H)

550 x 535 x 825mm

Oven size (W x D x H)

360 x 340 x 280mm (34 Litres)

Firebox size (W x D x H)

360 x 340 x 395mm

Total weight of appliance

120kg

Room Output

In normal operation the Baker's Oven can be controlled using the primary air vent to produce 
the following heat output range:

Room heat output: 

5.5 kW – 10.6kW

Summary of Contents for NBO

Page 1: ...NECTRE WOOD STOVES Installation Operating Instructions Baker s Oven Model NBO 10 Tested to EN12815...

Page 2: ...ed technical drawing for other dimensions not listed here Specification Baker s Oven Nominal heat output 10 6 kW Total efficiency 77 3 Mean CO Emission at 13 O2 0 55 Mean flue gas temperature 274 9 C...

Page 3: ...perature NOTE the temperature gauge on the oven door is only a guide to the temperature in the oven We have found that when the gauge is reading around 100 C the internal oven temperature is more like...

Page 4: ...a chimney fire close the primary air spindle control to suffocate the fire After a prolonged period of no use the chimney and the appliance should be checked for blockages prior to lighting Maintenan...

Page 5: ...eets Over time these can burn through In such an event new ones can be sourced from your dealer and re hung inside the firebox Key Environmental Considerations To minimise the impact on the environmen...

Page 6: ...minimum clearance from the corner edge of the appliance to the nearest combustible surface is 250mm If the walls adjacent to the appliance are a non combustible material and minimum 75mm thick then t...

Page 7: ...f the chimney with a register plate and fit the flue pipe up through the plate and continue the flue until it terminates outside the chimney in accordance with Building Regulations Approved Document J...

Page 8: ...s warranty Pecan Engineering Pty Ltd assumes no responsibility for the labour costs involved in removing or replacing the stove Nor shall Pecan Engineering Pty Ltd be liable for any injury loss or dam...