background image

8 | 

P a g e

 

N550 Bakers Oven | Installation Manual  

 

 

 

 

Chimney Connection 

 

The chimney connector is a single walled pipe used to connect the stove to the chimney. For use 

with  the  N550  Bakers  Oven 

the  chimney  connector  MUST  be  6” 

(150mm)  in  diameter,  with  a 

minimum thickness of 24-gauge black steel or 26-gauge blued  steel.  The  chimney connector 

must be suitable for solid fuel, in good condition, and kept clean. 

 

Aluminum and galvanized steel pipe is not acceptable for use with the N550 Bakers Oven. These 

materials cannot withstand the extreme temperatures of a wood fire and can give off toxic fumes 

when fired. 

 

DO NOT USE THE CONNECTOR PIPE AS A CHIMNEY. 

 

Each chimney connector or stove pipe section must be installed to the stove flue collar and to 

each other with the male (crimped) end toward the stove, as per figure 5.a. Attach each of the 

sections to one another with three equidistant metal screws, as per figure 5.b. 

 
 

 

 

Figure 5. a) Chimney connection, b) Stove pipe attachment 

 

 

This prevents any amount of condensed or liquid creosote from running down the outside of the 

pipe or the stovetop. All joints, including the flue collar connection must be secured with three 

sheet metal screws to ensure that the sections do not separate. 

 

For  the  best  performance,  the  chimney  connector  should  be  as  short  and  direct  as  possible, 

with  no  more  than  two  90

° 

elbows.  The  maximum  horizontal  run  is 

36”

  (915mm)  and  a 

recommended  total  length  of stove  pipe  should  not  exceed  10  feet.  Always  slope  horizontal 

runs upward 

¼”

 per foot toward the chimney. 

 

No  part  of  the  chimney  connector  may  pass  through  an  attic  or  roof  space,  closet  or  other 

concealed  space,  or  through  a  floor  ceiling.  All  sections  of  the  chimney  connectors  must  be 

accessible for cleaning. Where passage through a wall or partition of combustible construction is 

desired, the installation must conform to NFPA 211 or CAN/CSA-B365, and is also addressed in 

this manual. 

Summary of Contents for N550

Page 1: ...260 6643 Email info pecan eng com au ENGLISH INSTALLATION INSTRUCTION MANUAL CA O se re e re m efore r se r ew ve re f m re r er m ge j r r eve e m r er co v r w rr T OT CE f ove r er e se f re m re r r fe f w e r c s Never se make f com r e r g e of ove C g or f re off ci erm re r ct re reme r re English French versions available www nectre com Français Anglais versions disponibles www nectre com...

Page 2: ... ANY AIR DISTRIBUTION DUCT OR SYSTEM DO NOT ELEVATE THE FIRE BY USE OF A LOG CRADLE OR GRATES BUILD FIRE DIRECTLY ON A 1 INCH LAYER OF ASH SPREAD EVENLY OVER THE BASE OF THE FIREBOX DO NOT STORE FUEL UNDERNEATH THE APPLIANCE WITHIN THE SPECIFIED INSTALLATION CLEARANCE AREAS OR WITHIN THE SPACE REQUIRED FOR CHARGING AND ASH REMOVAL ALWAYS CLOSE THE DOOR AFTER THE IGNITION LEAVING DOOR OPEN CAN CAUS...

Page 3: ...N550 Bakers Oven Installation Manual 3 P a g e Certification Label ...

Page 4: ...aded end of the handle with the extended nut attached to the by pass damper Screw the handle all the way into the nut until tight The position of the handle should be at approximately 11 o clock when the damper is open and 1 o clock when the damper is shut DO NOT ALTER THE DAMPER ADJUSTMENT RANGE TO INCREASE FIRING FOR ANY REASON INSTALLING FIRE BRICKS The stove comes with 4 fire bricks 9 x 4 x 1 ...

Page 5: ... the two support lugs with the 4 100mm strip located between them Raise the lower rear edge of the baffle plate to rest on top of the brick retainer With the baffle plate in its correct position ensure it is pushed all the way back so that it doesn tfall INSTALLING TOP AIR CONTROL ROD A stainless steel rod with a thread at one end and black knob on the other will have been supplied in the stove Pa...

Page 6: ...l board with a k factor of 0 29 the total R value of the system Rtotal is 4 brick C 1 25 1 2 mineral board K 0 29 Rbrick 1 1 25 Rmineral 1 0 29 x 0 5 0 8 1 724 Rtotal Rbrick Rmineral Rtotal 0 8 1 724 2 524 In this example the R value is greater than 2 12 required and therefore this floor protector isa suitable combination that provides the required thermal protection In the USA the floor protector...

Page 7: ...owing clearances may only be reduced by means approved by the regulatory authority A combustible surface is anything that can burn i e sheet rock wall paper wood fabrics etc These surfaces are not limited to those that are visible and include materials that are behind non combustible materials If you are not sure of the combustible nature of a material consult your local fire officials Figure 4 a ...

Page 8: ... another with three equidistant metal screws as per figure 5 b Figure 5 a Chimney connection b Stove pipeattachment This prevents any amount of condensed or liquid creosote from running down the outside of the pipe or the stovetop All joints including the flue collar connection must be secured with three sheet metal screws to ensure that the sections do not separate For the best performance the ch...

Page 9: ...aintained as per the installer s complyingmethod Factory Built Chimney When a metal prefabricated chimney is used the manufacturer s installation instructions must be followed You must also purchase from the same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clea...

Page 10: ...a masonry chimney special methods are needed Refer to figure 7 The chimney must have either a clay liner or a suitably listed stainless steel liner If the masonry chimney has a square or rectangular liner that is larger in cross sectional area than a round 6 150mm flue it should be relined with a suitably listed 6 150mm stainless steel liner Do not downsize the flue to less than 6 unless the venti...

Page 11: ...er nearby obstructions The chimney must be at least 3 900mm higher than the highest point where it passes through the roof and at least 2 600mm higher than the highest part of the roof or structure that is within 10 300mm of the chimney measured horizontally Refer to figure 8 Figure 8 Chimney height requirements Appliance Dimensions Figure 9 Dimensions mm for installer ...

Reviews: