Most building regulatory Authorities in Australia require any 
wood heater installation to comply with Installation Standard 
AS/NZS 2918:2001. Different states and councils may have 
varying regulations. Check local building regulations before 
installing the appliance. 

All Nectre wood heaters have been tested to ensure that they 
will meet the appropriate safety Standard requirements if the 
instructions in this manual are followed. As the safety and 
emissions performance can be affected by altering the 
appliance, no modifications are allowed without written 
permission from the manufacturer. 

WE RECOMMEND THAT THE INSTALLATION OF YOUR 
NECTRE WOOD HEATER BE CARRIED OUT BY A QUALIFIED 
INSTALLER. 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE 
INSTALLED IN ACCORDANCE WITH AS/NZS 2918:2001 AND 
THE APPROPRIATE REQUIREMENTS OF THE RELEVANT 
BUILDING CODE OR CODES. 

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH 
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS 
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE 
REGUALTORY AUTHORITY, I.E. THE APPLIANCE SHALL BE 
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING 
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’. 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT 
BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY 
IS CONSIDERED TO BE IN BREACH OF THE APPROVAL 
GRANTED FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 
4013. 

CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM 
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING 
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY 
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION 
IS CONSIDERED, THE MANUFACTURER SHOULD BE 
CONSULTED IN THE FIRST INSTANCE. 

CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS 
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION 
UNSAFE. 

 

 

2.1 

Positioning the Heater

 

First review the necessary clearances specified below before 
considering where to position the heater.  

Also check the practicability of installing the flue system in 
relation to any obstructing roof beams before positioning 
the heater. 

These clearance distances can only be reduced if the 
surrounding walls are made of non-combustible material, 
eg. Stone, brick, or concrete.  If non-combustible material, 
distance can be reduced to 100 mm. Alternatively, shielding 
of the wall(s) can reduce clearances (refer to next section 
for more detail). 

Depending on the type of flue shielding used, the clearances 
to combustible surfaces varies. 

2.1.1  Standard Installation:

  

 

 

 

Flue shielding 

A (mm) 

B (mm) 

C (mm) 

900mm shield 

450 

125 

400 

Decro-mesh with 
900mm inner reflector 

350 

125 

400 

 

 

THE INSTALLATION INSTRUCTIONS IN THIS 
MANUAL APPLY TO THE NECTRE MK2 LE. 

IT HAS BEEN TESTED FOR EMISSIONS AND EFFICIENCY 
AND COMPLIES ACCORDING TO AS/NZS 4012:1999 & 
AS/NZS 4013:1999. 