9
3.
FITTING A NEW DOOR SEAL
Remove the door from the heater and lay it horizontally on
a work-bench.
1.
Remove any old seal from the door.
2.
Clean out the groove in the door that held the seal
using a flat-end screw driver or equivalent.
3.
Run a thin bead of clear roof and gutter silicone
along the groove.
4.
Starting at one end, press the new door seal rope
into the groove on the door.
5.
Refit the door and close.
APPLY SILICONE
4.
FITTING NEW DOOR GLASS
Due to the curvature of the glass, the door seal and door
seal retainers must also be removed from the door in order
to gain access to the glass.
To replace the door glass, remove the door from the heater
and lay it horizontally on a work-bench.
1.
Remove door seal from the door.
2.
Clean out the groove in the door that held the seal
using a flat-end screw driver or equivalent.
3.
Using 2.5mm hex key, remove four M4 screws
holding the door seal retainers to the door.
4.
Six small stainless steel tabs hold the glass in place.
Remove the screws from the stainless steel strips
with a 4mm hex key.