Ceiling 

Ceiling Plate with spacers 

Seismic restraints through 
floor protector into floor  

Floor Protector 

Casing Cover 

ADD Cowl 

150mm Flue Pipe 

1200 Flue 
Shield Guard 

250mm 

250mm 

250mm sq timber frame 

3000mm 

Min 600mm above ridge if within 3000mm.  
Or if beyond 3000mm a min 1000 above roof  
 

Weather tight 
Flashing E2 

Tested Freestanding 150mm Flue System 

Installed to AS/NZS2918:2001 

Inner liner must rise 
min 200mm above 
roof cladding 

1200 Combination Liner 

• 

150mm Stainless Flue 

• 

200mm Inner Galv Liner 

• 

250mm Outer Galv Liner 

600mm Extension 

Combustible Floor  
and/or Floor Coverings 

Solid Fuel Appliance 

Minimum 4800mm 
Top of floor protector 
to top of flue system 

PDF created with pdfFactory trial version 