Necta Colibri Instructions For Installation, Use And Maintenance Manual Download Page 22

18

© by NECTA VENDING SOLUTIONS SpA

03-2003 217 00

When in “programming” mode the selection buttons have the
following functions:

WATER FAILURE

The machine locks if the water level in the tank falls to less
than approximately 300 cc.

CUP FAILURE

When the empty cup column microswitch opens, the
column shift motor is activated. If after one full turn of the
cup dispenser the microswitch is not closed the message
“No cups” is displayed and the machine locks.

WATER LEAK FAILURE

If water is requested by the air-break without having been
used (selections, cleaning etc.) the machine will block
further water requests.

ROTOR FAILURE

Failed computation of the volumetric counter within a max.
given time.

COFFEE UNIT FAILURE

This failure is due to a mechanical lock of the unit or when
the unit is not present. The machine is not locked, but all
coffee-based selections are disabled.

COFFEE FAILURE

If after a period of 15 seconds of grinding coffee a dose is
not obtained, all coffee-based selections are disabled.

COFFEE RELEASE FAILURE

If after releasing the ground coffee dose the microswitch of
the coffee doser unit indicates the presence of coffee in the
doser chamber, all coffee based selections are disabled.

CUP RELEASE FAILURE

If after releasing one cup the positioning microswitch is not
triggered the control software disconnects power from the
release motor and the machine locks.

LIQUID WASTE FULL

If the machine is equipped with a liquid waste container
(housed in the cabinet) fitted with an overflow warning
device, the machine locks.

CHANGER FAILURE

The change-giver coin mechanism is not working or does
not communicate.

BILL VALIDATOR FAILURE

The bill accepter is not working or does not communicate.

CASHLESS FAILURE

The key device or the magnetic card is not working or does
not communicate.

1 - 

Previous function / Increase data item (+1)

2 - 

Exit function / Cancel change

3 -

Machine installation

4 -
5 - 

Next function / Decrease data item (- 1)

6 - 

Confirm function / confirm data

7 - 

Change data item

8 -

Reset failures

The buttons preceded by the symbol allow scrolling through
the menu or changing of data; the other buttons are used
directly for that function.

DISPLAYING THE EXISTING FAILURES

When the “Present failures” function from the “program-
ming” menu is displayed, press the confirm button “ ” to
display the error code of the current failure; then keep
pressing button “ ” to display the error code of the next
present failure.
If no failures are present, when pressing the confirm button
“ ” the message “No Failure” is displayed.
The possible failures are indicated in the following cases:

AIR-BREAK FAILURE

The machine will lock if after dispensing water correspond-
ing to 150 pulses of the volumetric counter the microswitch
has not signalled the lack of water.

BOILER FAILURE

The machine will lock if after 10 minutes of heating from the
machine start, or from the last selection, the boiler fails to
reach the operating temperature.

COIN MECHANISM FAILURE

The machine will lock if it receives an impulse longer than
2 seconds on a validator line or there is no communication
with the serial coin mechanism for more than 30 seconds.

RAM DATA FAILURE

The data contained in the EEprom (i.e. the chip that stores
the setting variations) is wrong and must be retrieved from
the Eprom, thus losing all statistics information.
The message “INITIALISE” will start blinking on the dis-
play.

Summary of Contents for Colibri

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL DOC NO H 217U 00 EDITION 1 03 2003 UK English Colibr Espresso MDB Protocol...

Page 2: ......

Page 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Page 4: ......

Page 5: ...JUSTING THE MACHINE SETTINGS PAGE 13 STANDARD SETTINGS PAGE 13 ADJUSTING THE BREWING CHAMBER VOLUME PAGE 13 WATER TEMPERATURE CONTROL PAGE 13 ADJUSTING THE GRADE OF GRINDING PAGE 14 ADJUSTING THE COFF...

Page 6: ...top of the other and must always kept upright as indicated by the arrows on the packing INTRODUCTION This technical documentation is part and parcel of the vendingmachineandmustalwaysfollowthemachine...

Page 7: ...llowing mainte nance operations should be carried out by qualified personnel only who are trained in the correct use of the machine according to the standards in force The machine is sold without paym...

Page 8: ...ion for Main electrical circuit Board power supply transformer CAPACITY OF CONTAINERS g K s r e n i a t n o c f o y t i c a p a C o s s e r p s E s n a e b e e f f o C 2 k l i M 8 0 e t a l o c o h C...

Page 9: ...DRINKS IN OPEN CONTAINERS Ex plastic cups ceramic cups jugs Vending machines for drinks in open containers should be used only to sell and dispense drinks obtained by brewing products like coffee and...

Page 10: ...ers are all placed horizontally Replace the stirrer weight and the cover The stirrers must be burr free and not curved LOADING CUPS To load the cups do as follows open the door and remove the cover fr...

Page 11: ...prepared chlorine based detergent reinstall the feeders and the water funnels reinstall the powder deposit drawers and the powder funnels after thoroughly drying them After reinstalling all parts the...

Page 12: ...fill At least once a week they must be sanitised using coffee machine detergents and mechanically removing all visible residue and product layers Fig 7 1 Dispensing compartment drip tray Fig 6 1 Sugar...

Page 13: ...c should be left within the reach of children as they are potentially dangerous Packing materials must be disposed of in authorised containers and the recyclable ones must be recovered by qualified co...

Page 14: ...he main switch should be capable of withstanding the peak load required and at the same time ensure proper omnipolar disconnection from the power grid with an opening gap of the contacts of at least 3...

Page 15: ...the condition of air break full or empty pump electrical functioning and water flow and boiler pressure When the machine is completely empty the No Water failure is indicated When the programming but...

Page 16: ...see Fig 11 The ratiomotor handle engaged with the disk 2 located outside of the assembly rotates by 180 making the brew chamber swing and lowering the upper piston 3 see Figure 12 Due to the water pr...

Page 17: ...ton 5 Pre brewing spring 6 Swinging lever STANDARD SETTINGS The vending machine is supplied with the following set tings coffee temperature at the spout approx 70 80 C instant product temperature at t...

Page 18: ...isplaying credit inserted Out of service Machine switched off Drink in process Drink preparation Temperature Wait time before reaching operating temperature Sel Disabled Selection disabled Coffee off...

Page 19: ...tion for 4 seconds permitting the test dispensing provided for each function N B For espresso coffee based selections only the additions are dispensed with the partial dispensing of powder and water i...

Page 20: ...ecisely With setting to VALIDATOR or TOTALIZER 1 counter by single selection 2 counter by single price 3 failure counter 4 counter by type of coin cashed 5 total cashed counter With setting to MDB 1 c...

Page 21: ...to exit the function PROGRAMMING When the programming button located on the internal side of the push button board see Fig 19 is pressed twice the machine will be set to Programming mode The message...

Page 22: ...chanism is not working or does not communicate BILL VALIDATOR FAILURE The bill accepter is not working or does not communicate CASHLESS FAILURE The key device or the magnetic card is not working or do...

Page 23: ...he confirm button to display the price number referred to in the price table When pressing correction button this value will start blinking and can be modified as necessary The buttons which control p...

Page 24: ...for the user by adding a number of coins between 0 and 15 to the programmed number of coins to set the full change tubes status DISPENSING BUTTONS This function is used to enable or disable the button...

Page 25: ...ns Since this is a control tool used only by the vending operator a 4 digit password must be entered After entering the password it is possible to set the number of selections after which the machine...

Page 26: ...s which are defined as sweetened but not dispense sugar for selections which are defined as unsweetened The settings defined with the selection configuration are used also for complete test selections...

Page 27: ...tion of chemical agents the stainless steel and varnished surfaces should be kept clean by using mild detergents solvents must not be used Never use water jets to clean the machine BREWING UNIT MAINTE...

Page 28: ...see Fig 17 processes the information from the push buttons and from the payment system it also controls the actuations and the push button board The 15 V AC voltage required for board operation is sup...

Page 29: ...Signals free vend jug facilities 5 To the display board 6 Display contrast adjusting trimmer 7 Programming button 8 Cleaning button 9 RS232 port 10 To the programmer 11 Display board Fig 18 1 Power s...

Page 30: ...t drip tray 4 Drip tray drain boss 5 Drain pipe 6 Liquid waste container float 7 Non return valve 8 Air break 9 Boiler 10 Coffee brewer pump 11 Volumetric counter 12 Water supply pump 13 Water supply...

Page 31: ...ELECTION READING DATA P Paid dispensing G Free dispensing T Test dispensing Statistics Display Statistics Statistic N 1 Sel N 1 P xxxx Sel N 1 G xxxx Sel N 1 T xxxx Sel N 8 P xxxx Sel N 8 G xxxx Sel N...

Page 32: ...5 Excess Aud 6 Releasing tubes Aud 7 Loading tubes Aud 8 Cash sales Aud 9 Cashed bills Aud 10 Charge key Aud 11 Sales with key Audit 1 XXXX Statistic N 4 Audit 11 XXXX USING AN MDB PAYMENT SYSTEM FAI...

Page 33: ...ter a few seconds all data is reset with the exception of the general counter Confirm Complete sel Selection 4 Sec Powder only Selection 4Sec Water only Selection 4 Sec No accessories Selection 4 Sec...

Page 34: ...ous function 2 Grind and release a coffee dose 3 Dispense sugar 4 Autotest 5 Next function 6 Rotate coffee unit 7 Release cup 8 Empty air break Statistics No accessories Fill tubes Credit XXXX TUBES C...

Page 35: ...e failure N 11 Coffee release N 12 Cup release N 13 Liquid waste full N 14 Changer N 15 Bill validator N 16 Cashless Z1 XXXX I3 Water doses Price N 1XXXX Price N 8 Set Prices Set Prices Buttons POWDER...

Page 36: ...rm function confirm data 7 Change data item 8 Reset failures BASIC COIN VALUE AND DECIMAL POINT POSITION 0 to 3 Previous price PRICE VALUE AND BUTTON STATUS Next price Set Prices Set Prices Buttons Bu...

Page 37: ...confirm data 7 Change data item 8 Reset failures Basic unit dP Payment systems Validator VALIDATOR SETTING Credit Power supply 12 24 V Coin line value A to F Line A Credit Excess credit available Val...

Page 38: ...Change data item 8 Reset failures XXXX 1 XXXX 1 XXXX 1 XXXX 1 Maximum change Value Value Maximum credit Value Value XXXX XXXX Coin 1 Coin 1 Accepted coins Yes Coin 1 Coin 1 Yes Not accepted coins Empt...

Page 39: ...5 Next function Decrease data item 1 6 Confirm function confirm data 7 Change data item 8 Reset failures Payment systems Machine code Initialising Confirm Tank Tank Type of doses for Korea Working Li...

Page 40: ...sing without cups Password Espresso coffee Instant P nnnn A nnnn P nnnn A nnnn P nnn A nnnn Upon entering the 4th digit the new value is confirmed P No of programmed selections A No of selections made...

Page 41: ...Confirm function confirm data 7 Change data item 8 Reset failures If the message is ON Selection counter Prom message Message xxxxxxxxxxxx To access programming Password Password X ON ON ON OFF ON OF...

Page 42: ...ction Config Cup release ON Cup release ON Enable Disable ON OFF Stirrer release ON Stirrer release ON Enable Disable ON OFF Sugar ON Sugar ON Enable Disable ON OFF Button 1 Buttons 1 to 8 Dati sconto...

Page 43: ...ITCH IP DOOR SWITCH IPF WASTE CONTAINER OVERFLOW SWITCH IVA EMPTY BOILER MICRO SWITCH IVB EMPTY CUP DISPENSER MICRO SWITCH KC1 COFFEE BOILER CUTOUT KS1 SAFETY CUTOUT LCD LIQUID CRYSTAL DISPLAY M COFFE...

Page 44: ......

Page 45: ...Colibr 220 V 60 Hz...

Page 46: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 47: ...ept any responsibility for any inaccuracies contained in this publication which can be ascribed to printing and or transcription errors All instructions drawings tables and information contained in th...

Page 48: ......