background image

© by NECTA VENDING SOLUTIONS SpA

31

00301 162-00

Reading data

DISPLAYING STATISTICS

PREVIOUS FUNCTION/
DECREASE DATA UNIT (-1)

NEXT FUNCTION/
INCREASE DATA UNIT (+1)

DELETE DATA/
EXIT FUNCTION

CONFIRM DATA/
CONFIRM FUNCTION

CHANGE DATA

Automatic data reading
scrolling at one second
intervals

MDB 

AUDIT

Press button "8 " to display
statistics for each selection
(1 - 8)

D

ISPENSING

 

BY

SELECTION

Refer to the selection dose
table for the correspondence
between dose code and
water or powder dose

P = paid selections

F = free selections

T = test selections

Total selections without cup

D = discounted selections

Sel. N.  8 G= xxxx

Sel. N. 8 D= xxxx

Sel. N.  8 T= xxxx

Sel. N.  8 P=xxxx

Sel. N. 1 D= xxxx

Sel. N. 1 T= xxxx

Sel. N. 1 F= xxxx

Sel. N. 1 P=xxxx

No cups

Statistic N. 2

Audit 12 = XXXX

Audit 0 = XXXX

Statistic N. 1

1 -Money in the tubes
2 -Money to the tubes
3 -Money to the box
4 - Change return
5 - Excess
6 - Releasing tubes
7 - Filling tubes
8 - Cash sales
9 -  Cashed bills
10 - Charging key
11 - Sales with key
12 - Money dispensed
      manually

Summary of Contents for Brio 250

Page 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English DOC NO H 162U 00 EDITION 1 03 01 Brio 250 Espresso Espresso Plus MDB Protocol...

Page 2: ......

Page 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Page 4: ......

Page 5: ...PAGE 11 STANDARD SETTINGS PAGE 12 ADJUSTING THE BREWING CHAMBER VOLUMEPAGE 12 ADJUSTING THE GRADE OF GRINDING PAGE 12 ADJUSTING THE COFFEE DOSE PAGE 12 WATER TEMPERATURE CONTROL PAGE 12 MAINTENANCE PA...

Page 6: ...imme diately Under no circumstances should they be pre served and or packed for later consumption Anyotheruseisunsuitableandthuspotentiallydangerous INTRODUCTION This technical documentation is part a...

Page 7: ...ained in the correct use of the machine according to the standards in force The machine is sold without payment system therefore the installer of such system has sole responsibility for any damage to...

Page 8: ...rmer Executive power supply transformer CAPACITY OF CONTAINERS Coffee beans 1 2 Kg Decaffeinated coffee 0 7 Kg Sugar 1 9 Kg Powdered milk standard 0 8 Kg Powdered milk plus 1 0 Kg French vanilla 1 9 K...

Page 9: ...e Fig 3 INSERTING THE LABELS The menu and instruction labels as well as the self adhesive labels to identify the product containers are supplied with the machine and must be inserted or at tached at t...

Page 10: ...the door see Fig 6 The labels with the selection menu and the instructions supplied with the machine must be inserted at the time of installation referring to the selection dose table Fig 5 1 Lift co...

Page 11: ...bill validator key magnetic card reader or cashless that can be used in various combinations Compatibility for the housing of the payment systems must be checked by the installer under his own re spo...

Page 12: ...ss Maintenance mode to clean the mixer see relevant paragraph and add a few drops of the chlorine based detergent in the various funnels After disinfection thoroughly rinse all components to ensure th...

Page 13: ...e stirrer weight The stirrers must be burr free and not curved CLEANING THE LIQUID WASTE TRAY The liquid waste tray can be removed easily for emptying and cleaning Ifthespecialpinsfittedonthecontainer...

Page 14: ...reverse order WEEKLY CLEANING OF BREWER UNIT At every refill or at least once a week any powder residue should be removed from the external parts of the brewer unit especially from the coffee funnel...

Page 15: ...a pause of 3 seconds the pre brewing spring 5 will discharge the water through the third way of the dispensing solenoid valve lightly pressing the used coffee dose Bycompletingitsrotation theratiomot...

Page 16: ...g lever 5 Reference notches N B Afteradjustmentofthegradeofgrinding atleast 2 test selections must be performed in order to check the new grade of the ground coffee the finer the grade of grinding the...

Page 17: ...achine To prevent oxidation or the action of chemical agents the stainless steel and varnished surfaces should be kept clean by using mild detergents solvents must not be used Never use water jets to...

Page 18: ...hree different operating modes are provided for the machine accordingly the buttons may have different func tions based on the preset mode of the buttons The available operating modes are as follows D...

Page 19: ...llowing functions Complete Sel Dispensing test including cup sugar and stirrer Powder only Dispensing powder only Water only Dispensing water only No accessories Dispensing test without cup sugar and...

Page 20: ...tting the sales price of bands with sales at a different price Set jug number of consecutive selections with jug facilities key Set language language of displayed messages Set waste counter number of...

Page 21: ...LL VALIDATOR FAILURE The bill accepter is not working or does not communicate CASHLESS FAILURE The key device or the magnetic card is not working or does not communicate SETTING THE WATER AND POWDER D...

Page 22: ...mains automatic cup dispensing Therefore after initialising the machine must be reconfigured FAST CYCLES When this function is enabled some of the time that is useful for improving the drink quality i...

Page 23: ...the user by adding a number of coins between 0 and 15 to the programmednumberofcoins tosetthe fullchangetubes status DISPENSING BUTTONS This function enables or not the buttons on the coin mechanism u...

Page 24: ...playthemessage Confirm before confirming connect the printer press the confirm button 2 to start printing DISPLAYING THE STATISTICS Press the statistics display button 8 to display in a sequence at 1...

Page 25: ...blinking indicates that the micro processor is working correctly the red LED indicates the operating status of the boiler heating element PUSH BUTTON BOARD This board controls the alphameric display t...

Page 26: ...ID VALVE K17 MF2 INSTANT MIXERS 2 EXPANSION BOARD model plus only K1 MD5 DECAFFEINATED DOSER DEVICE L E D O M T N A T S N I O S S E R P S E 5 P I D I N I M N O F F O R E P M U J 2 1 3 2 R E R R I T S...

Page 27: ...162 00 HYDRAULIC SYSTEM 1 Water inlet solenoid valve 2 Volumetric counter 3 By pass 4 Vibration pump 5 Mechanical filter 6 Air break 7 Coffee unit 8 Decaffeinated doser device some models only 9 Boil...

Page 28: ...uid waste full N 8 Volumetric counter N 9 Tea brewer N 9 Coffee unit N 10 Coffee failure N 11 Coffee release N 12 Changer N 13 Bill validator N 14 Cashless DISPLAYING FAILURES WATER DOSES Refer to the...

Page 29: ...CHANGE DATA BASIC COIN VALUE AND DECIMAL POINT POSITION 0 to 3 Previous price PRICE VALUE AND SELECTION STATUS Enable selection Disable selection Next price Set Prices Sel Selection 1 A Selection 1 A...

Page 30: ...done after initialising the RAM MACHINE IDENTIFICATION CODE When pressing the change button the first digit starts blinking The buttons take on numeric values When pressing a button the blinking digit...

Page 31: ...the blinking digit takes on that value and the next digit starts blinking The password corresponds to the sequence 4 2 3 and 1 P A nnnn P A nnnn P nnnn A nnnn P nnnn A nnnn Instant Espresso coffee Pas...

Page 32: ...evel tubes Value XX XX 1 XX 1 Value 0 to 15 Disp buttons Enabled Disabled Accepted bills Bill 1 Bill 1 Yes Bills 1 16 Yes No Enabled MINIMUM LEVEL OF TUBES DISPENSING BUTTONS ACCEPTED BILLS Maximum ch...

Page 33: ...CREASE DATA UNIT 1 DELETE DATA EXIT FUNCTION CONFIRM DATA CONFIRM FUNCTION CHANGE DATA SETTING INTERNAL TIME E Enable D Disable X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 Washing xx xx Ye...

Page 34: ...f time band with differentiated prices X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 XXXX 1 XXXX 1 XXXX Pr N 1 Set disc prices Price N 1XXXX Price N 8 FAILURES LIST Set washing Set band Start xx xx End xx xx Start...

Page 35: ...selection dose table for the correspondence between dose code and water or powder dose P paid selections F free selections T test selections Total selections without cup D discounted selections Sel N...

Page 36: ...ng at one second intervals FAILURE COUNTERS LIST OF FAILURES N 1 Air Break N 2 Boiler N 3 Payment system N 4 EEprom data N 5 Water failure N 6 Cup failure N 7 Liquid waste full N 8 Volumetric counter...

Page 37: ...MICRO SWITCH IVB EMPTY CUP DISPENSER MICRO SWITC JUG JUG FACILITIES SWITCH KC1 COFFEE BOILER CUTOUT KS1 SAFETY CUTOUT LF1 LAMP M COFFEE UNIT MOTOR MAC GRINDER MD1 INGREDIENT MOTOR INSTANT MDTE FRESH...

Page 38: ...NECTA VENDING SOLUTIONS SpA Sx30504...

Page 39: ...Brio Caff 120V UL...

Page 40: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 41: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 42: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 43: ...t any responsibility for any inaccuracies contained in this publication which can be ascribed to printing and or transcription errors All instructions drawings tables and information contained in this...

Page 44: ......

Reviews: