VOL.2-330
MCMG [SCA-4LC2COTA/MG-4LC2COTA]
MC part of MCMG is controlled by Internal PHE which is embedded in the Telephony Server. About the pro-
cedure for the Internal PHE data assignment, refer to Vol.1, Chapter 2, “2. IP Related Basic Programming” in
this manual. The explanation of PHs including Internal PHE is also there.
[4] MC Data Assignment
Assign the system data, according to the station numbering plan. Refer to the following for the prerequisite min-
imum data.
ASYD: Assignment of System Data
SYS1, INDEX 4, b2-b3
Assign the Releasing Method for Station-to-Station Calling Service
00 = Calling Party release
01 = Called Party release
10 = First Party release
11 = Both Party release
Normally, “10” = First Party release is assigned.
SYS1, INDEX 16
Assign the number level on station number composition
b0: 0/1 = 1-digit station number is not used/used
b1: 0/1 = 2-digit station number is not used/used
b2: 0/1 = 3-digit station number is not used/used
b3: 0/1 = 4-digit station number is not used/used
b4: 0/1 = 5-digit station number is not used/used
SYS3, INDEX 0
Assign the ringing pattern when a call from the C.O. line terminates to a station. Normally, “21” is assigned
in hexadecimal (1 second ringing, 2 second pause).
For details, refer to Command Manual.
SYS3, INDEX 1
Assign the ringing pattern when a station is called from another station (Ringing Pattern 1).
Normally, “42” is assigned in hexadecimal (2 second ringing, 4 second pause).
For details, refer to Command Manual.
SYS3, INDEX 2
Assign Station Release Timer (TS - release timing when connected to an ORT) and Hooking Timer (TL -
SHF maximum timing). Normally, “91” is set in hexadecimal (TS = 120 milliseconds, TL = 1,080 milli-
seconds).
For details, refer to Command Manual.
ASYDL: Assignment of System Data (LDM)
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...