Appendix B
CD-ETIA Limitations
S
ECTION
1
L
IMITATIONS
When using the SV8100 withe NetLink it is recommended to use an external Ethernet
switch in place of the CD-ETIA for the Secondary systems.
This is because when NetLink integrates the systems together it performs a slot reset
on all Secondary systems. this action can cause the Netlink connection to fail and
recover in an endless loop due to the loss/recovery of the ethernet link.
There is no problem deploying the CD-ETIA blade in the Primary system or in any
systems that do not use Netlink.