49. MODEL NAME Request
Function
The external control equipment inquires the product code of the plasma
monitor.
Transmission Data
1FH 80H 60H 17H 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS
DATA00 : 1st character of the product code
DATA01 : 2nd character of the product code
:
DATA11 : 12th character of the product code
Received data
00
H
-09
H
:
0
-
9
80H
: - (Hyphen)
96H
:
(Blank)
10
H
-29
H
:
A-Z
Corresponding
character
A B C D E F G H I J
Received
data
(H) 10 11 12 13 14 15 16 17 18 19
Corresponding
character
K L M N O P Q R S T
Received
data
(H) 1A 1B 1C 1D 1E 1F 20 21 22 23
Corresponding
character
U V W X Y Z
Received
data
(H) 24 25 26 27 28 29
If there are fewer than 12 characters in the product code, product code
would be padded right with blanks.
Example: If the product code of your plasma monitor is “PX-42VP4G”, the
returned codes would be as follows.
DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H,
DATA05:25H, DATA06:1FH, DATA07:04H, DATA08:16H, DATA09:96H,
DATA10:96H, DATA11:96H