29. OSM Select
Function
The external control equipment switches on or off the on-screen menu (OSM) of
the plasma monitor.
Transmission Data
DFH 80H 60H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
ACK
7FH 60H 80H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
*Operation is as described in the table below.
On-Screen Menu (OSM)
Display of items and adjustments
on the menu
Volume display, input display, and
screen size display
Operation
When screen
menu is ON
When screen
menu is OFF
When screen
menu is ON
When screen
menu is OFF
Remote
control
operation
Yes Yes Yes No
Personal
computer
control
operation
No No Yes No
30. OSM ADJ. Gain Data
Function
The external control equipment sets the position of the OSM menu of the
plasma monitor.
Transmission Data
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS
DATA00 : OSM ADJ. Gain Flag
02H
DATA01
01H
:
1
:
06H : 6
ACK
7FH 60H 80H 1AH 01H DATA00 CKS
DATA00 : OSM ADJ. Gain Flag 02H
27
Summary of Contents for PlasmaSync 42VP
Page 2: ......
Page 54: ...NEC plasma display External Control Manual for PX 50XM3 PX 42XM2 PX 42VP4 ...