CHAPTER 6 PERIPHERAL HARDWARE FUNCTION
126
User’s Manual U10676EJ3V0UM
(1) Timer counter mode registers (TM0, TM1, TM2)
A timer counter mode register (TMn) is an 8-bit register that controls the corresponding timer counter. Figures
6-26 to 6-28 show the formats of the various mode registers.
The timer counter mode register is set by an 8-bit memory manipulation instruction.
Bit 3 of this register is a timer start bit and can be manipulated in 1-bit units independently of the other bits.
This bit is automatically reset to “0” when the timer starts operating.
All the bits of the timer counter mode register are cleared to “0” when the RESET signal is asserted.
Examples 1.
To start timer in interval timer mode of CP = 5.86 kHz (at f
X
= 6.0 MHz)
Note
SEL
MB15
; or CLR1 MBE
MOV
XA, #01001100B
MOV
TMn, XA
; TMn
←
4CH
2.
To restart timer according to setting of timer counter mode register
SEL
MB15
; or CLR1 MBE
SET1
TMn.3
; TMn.bit3
←
1
Note
CP = 4.10 kHz when the
µ
PD754244 is operating at fx = 4.19 MHz.
CP = 977 kHz when the
µ
PD754144 is operating at f
CC
= 1.0 MHz.
Remark
n = 0 to 2