57
Response
4
When the command succeeds
23h 05h
<ID1>
<ID2>
10h
<DATA01>
-
<DATA16>
<CKS>
Data part
Item
Description
DATA01
Adjusted value status
00h
Display not possible
01h
Adjustment not possible
02h
Adjustment possible
FFh
The specified gain does not exist.
DATA02
Upper limit of the adjustment range (low-order 8 bits)
DATA03
Upper limit of the adjustment range (high-order 8 bits)
DATA04
Lower limit of the adjustment range (low-order 8 bits)
DATA05
Lower limit of the adjustment range (high-order 8 bits)
DATA06
Default value (low-order 8 bits)
DATA07
Default value (high-order 8 bits)
DATA08
Current value (low-order 8 bits)
DATA09
Current value (high-order 8 bits)
DATA10
Wide adjustment width (low-order 8 bits)
DATA11
Wide adjustment width (high-order 8 bits)
DATA12
Narrow adjustment width (low-order 8 bits)
DATA13
Narrow adjustment width (high-order 8 bits)
DATA14
Whether the default value is valid or invalid
00h
The default value is invalid.
01h
The default value is valid.
DATA15
DATA16
Reserved for the system
4
When the command fails
A3h 05h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>