6-5
Continue
Check the data enable of positive
polarity are output on P305 pin 42.
Failure point
1) I401 failure
2) Printed wire broke between I401 and P305 pin 42.
Check the data signal output on
P305 R, G, B data pin.
OK
NG
Failure point
1) I401 failure
2) Printed wire broke between I401 and P305 data line
Failure point
1) The cable broke between P305 and LCD module.
2) LCD module failure.
OK
NG