NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 767
Time Display - D
term
T-18D
T-18D
Time Display - D
term
General Description
This feature provides a digital time display on a D
term
’s LCD.
Operating Procedure
No manual operation is required.
Service Conditions
1.
The time is displayed according to the clock in the PBX and is set via the MAINTENANCE
ADMINISTRATION TERMINAL (MAT) [M-18].
2.
Time is displayed automatically:
3.
Time is constantly displayed on the center line of the LCD.
4.
The time will not be displayed when a D
term
station is set for a second line MESSAGE WAITING
INDICATION -D
term
[M-85D] and MW/VMM is displayed.
5.
While NAME DISPLAY - SYSTEM [N-28], NAME DISPLAY - SYSTEM - CCIS [N-37], or NAME
DISPLAY WITHOUT - OAI - CCIS [N-37] 16-digit display is activated on the D
term
with 2-line LCD
display, the time is not displayed. When both the calling/called station are released from a station-to-
station call, the LCD of the calling/called station returns to the TIME DISPLAY.
Interactions
1.
Only the D
term
with display has the TIME DISPLAY feature capability.
2.
The calendar and time must be set via ATIM command.
Programming
STEP 1:
ATIMN
- Assignment of time data command for the FCCS network.
STEP 2:
ATIM
- Assignment of time data command must be used to provide the system with the date and time.
STEP 3:
ASDT
- The D
term
itself must be assigned. Assign to an LEN served by an 8DLC or 16ELC, with a
Telephone Equipment Class (TEC) of 12.
12:48 PM WED 27