CHAPTER 2 INSTALLATION
Installation for Remote Site
NEAX2000 IVS
2
Remote PIM System Manual
ND-70917 (E), Issue 1.0
Page 29
INSTALLATION FOR REMOTE SITE
Mounting DAIB Card for T1 / DAIE Card for E1
(1)
Before mounting the DAIB/DAIE card, set the MB switch to UP position,
and set the other switches to appropriate position. See
CHAPTER 4
.
(2)
Mount the DAIB/DAIE card in the MP slot on Remote PIM.
After mounting the card, set the MB switch to DOWN position.
Mounting DAIC Card for T1 / DAIF Card for E1
(1)
Before mounting the DAIC/DAIF card, set the MB switch to UP position, and set the other
switches to appropriate position. See
CHAPTER 4
.
(2)
Mount the DAIC/DAIF card in the AP slots (AP00-AP11) on Remote PIM.
A maximum of two DAIC cards can be mounted per Remote PIM.
A maximum of one DAIF card can be mounted per Remote PIM.
After mounting the card, set MB switch to DOWN position.
(3)
After mounting all DAIC/DAIF cards, set MB switch on DAIB/DAIE card to UP, and then
DOWN.
Mounting M10 Card
(1)
Confirm the correct switch settings. See
CHAPTER 4
.
(2)
Mount the M10 card in any one of LT slot on each PIM.
ATTENTION