ND-46550
(E)
CHAPTER
3
Page 29
Revision 2.0
2.1.5 BUS Cable Connection
(1)
Cable connection between BUS Card and the DAIA Card
Connect the DAIA card to the BUS card by the RMT PCM-0.3 CA and 17-TW-0.3 CONN CA-A, as shown in
Note:
Up to three DAIA cards can be connected directly by a daisy chain connection on one PIM. If two or three
DAIA cards are mounted on one PIM, the 17-TW-0.3 CONN CA-A is required. When the system is more
than one PIM configuration, the DAIA cards must be mounted on the first/last PIM due to the number of
connectors of a BUS card.
Figure 3-9 BUS-DAIA Cable Connection
(1) 1-PIM Configuration
BS00
DAIA
BS00
DAIA
DAIA
BS00
DAIA
DAIA
: RMT PCM-0.3 CA
: 17-TW-0.3 CONN CA-A
DAIA
BUS
DAIA
BUS
DAIA
DAIA
BUS
DAIA
DAIA
• When mounting 1 DAIA card
• When mounting 2 DAIA cards
PCM1
PCM0
CN2
CN1
CN2
CN1
PCM1
PCM0
PCM1
PCM0
• When mounting 3 DAIA cards
PCM1
PCM0
PCM1
PCM0
CN2
CN1
PCM1
PCM0
CN1
CN2
PIM0
PIM0
PIM0
DAIA