ND-70348 (E)
CHAPTER 4
Page 213
Revision 3.0
ASYDL
Note 1:
When office data is assigned by the MAT during 16-IMG system is in operation, office data (DM/LDM/
NDM) copy is executed from ACT side SP to ST-BY side SP/LP.
Every time office data is assigned by the MAT, the part of the data is copied to ST-BY side SP and each LP
when ASYDL, INDEX805, b1=0. Also office data copy is to be executed when the following operation is
performed:
• System Initialization
• Initialization for each Processor
• Execution of the CBCD command
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
804
b
0
Kind of tone when a call is transferred from Attendant Console
in case all the stations in a UCD group are busy;
0/1 = BT/RBT
Note:
Available for software Release 9 or later.
b
1
Transferring the busy information of Logical Route
0/1 = Out of service/In service
b
2
Not used
b
3
The number of digit for Internal Zone Paging group ID
0/1 = 2 digits/3 digits
Note:
Available for software Release 9 or later.
b
4
UCD Announcement Information
0 = Individual setting for each UCD group
1 = Common in all the UCD groups
Note:
Available for the software Release 9 or later.
b
5
~b
7
Not used
805
b
0
(For 16-IMG system)
Periodic Refresh for office data copy
Note 1
0/1 = Execute/Stop
b
1
(For 16-IMG system)
Partial copy every time office data is assigned
Note 1
0 = Execute
1 = Not execute (data copy is executed by CBCD command)
b
2
(For 16-IMG system)
Information of office data copy condition
Note 1
0/1 = – /Output System Message
0
b
3
~b
7
Not used
806~831
Not used
832
b
0
~b
7
FPC (Fusion Point Code) of the node connected with MC (Mes-
sage Center) in the same MC group
FPC: 1 ~ 253 (01 Hex. ~ FD Hex)
Note: