ND-70348 (E)
CHAPTER 4
Page 205
Revision 3.0
ASYDL
Note:
Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting
is fixed to “0”.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
578
b
0
Centralized Billing via Netfusing output text format of SMDR A
0/1 = ICS format/IMX format
0
b
1
~b
3
Not used
b
4
0/1 = SMDR A Apparatus with LAN interface is not used/used
Note
0
b
5
~b
7
Not used
579
b
0
Centralized Billing via Netfusing output text format of SMDR B
0/1 = ICS format/IMX format
0
b
1
~b
3
Not used
b
4
0/1 = SMDR B Apparatus with LAN interface is not used/used
Note
0
b
5
~b
7
Not used
580
b
0
Centralized Billing via Netfusing output text format of SMDR C
0/1 = ICS format/IMX format
0
b
1
~b
3
Not used
b
4
0/1 = SMDR C Apparatus with LAN interface is not used/used
Note
0
b
5
~b
7
Not used
581
b
0
Centralized Billing via Netfusing output text format of SMDR D
0/1 = ICS format/IMX format
0
b
1
~b
3
Not used
b
4
0/1 = SMDR D Apparatus with LAN interface is not used/used
Note
0
b
5
~b
7
Not used
582
b
0
~b
3
The number of the node to be polled in a polling.
0000 = 1
0001 = 1
0010 = 2
0011 = 3
0100 = 4
0101 = 5
0110 = 6
0111 = 7
1000 = 8
~
1111 = 8
Note 1:
This data is available since Release 5.
Note 2:
For numbers more than 8, assign the data value as 8.
0
b
4
~b
7
Not used
583
b
0
~b
2
The timing for transmitting the billing data of SMDR - Netfusing from the
node that accommodates the outgoing trunk to the node that accommodates
the called station.
000 = 8 sec.
100 = 8 sec.
001 = 2 sec.
101 = 10 sec.
010 = 4 sec.
110 = 12 sec.
011 = 6 sec.
111 = 14 sec.
b
3
~b
6
Not used
b
7
The timing for transmitting the polled billing data assigned at b
0
~b
2
is
0 = In Service