3-B PM C-level Infinite Loop (Permanent)
2.1 Repair Procedure
STEP 1:
Initialize the indicated FCH (PA-FCHA) card using the MB key. (MB key: Down
➔
Up
➔
Down).
Refer to
When the LED on the FCH card lights green and the related system messages are not displayed,
monitor the system for a while. Otherwise move to STEP 2.
Figure 7-3 How to Initialize the FCH (PA-FCHA) Card
STEP 2:
Replace the FCH card, following the procedure listed in
FCHA) card.”
M B
O PE
M B
O PE
Flip the M B key as follows to initialize the FCH card.
M B
O P E
FCH (PA-FCH A)
FRO N T VIEW
Anti-static Kit
O PE LED is O FF.
ATTENTION
Contents
S tatic S ensitive
Handling
P recautions Required
O PE LED lights
G REEN again.