CHAPTER 3
ND-70684 (E)
Page 20
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
2. Data Programming Procedure (DSS/BLF)
When assigning DSS/BLF data, perform the following procedure. “X” indicates the value should be tailored to
the existing system.
STEP 1:
ASYD
Assign the DSS/BLF to an even-numbered LEN level. (In this example LV 0 is used.)
Assign a station to be used for programming DSS keys (KYNs 31-60) to the subsequent LENS. (In
this example, LV 1 is used.
STEP 2:
AKYD
Assign key data for the 60 DSS keys. The upper 30 DSS keys (KYNs 1-30) are assigned using the
first port (LV 0 in this example) and the remaining lower DSS keys (KYNs 31-60) are assigned using
the second port (LV 1 in this example). Either KYN 1 or KYN 2 can be assigned first.
Be sure to assign the associated D
term
station number as the “Station Number of Prime Line.”
KYN 1 must be programmed as the DSS/BLF station that has been assigned by the ASDT command.
TN
:
X
STN :
200
LEN :
0 0 0 1 0 0
Even-numbered LEN level
TEC :
1 2
Fixed
RSC :
X
SFC :
X
TN
:
X
STN :
201
LEN :
0 0 0 1 0 1
Subsequent LEN level
TEC :
1 2
Fixed
RSC :
X
SFC :
X
TN
:
X
STN
:
200 or 201
TP
:
1
Buttons 1-40 are assignable
PRI
:
0
PL TN
:
X
PL STN :
400
Enter the associated D
term
as a PL STN.
S
:
0
= Off Hook Suppression is off
MWD
:
0
LN PRE :
0
= Prime Line Pickup
KYN
:
1
KY1
:
2
= Multi Line
KD
:
0
= Line
TN
:
X
STN
:
200 or 201
DSS/BLF number
RG
:
X
Summary of Contents for NEAX 2400 IMX
Page 4: ...TABLE OF CONTENTS ND 70684 E Page ii Revision 1 0 This page is for your notes...
Page 6: ...LIST OF FIGURES ND 70684 E Page iv Revision 1 0...
Page 8: ...LIST OF TABLES ND 70684 E Page vi Revision 1 0 This page is for your notes...
Page 22: ...CHAPTER 1 ND 70684 E Page 14 Revision 1 0 This page is for your notes...
Page 26: ...CHAPTER 2 ND 70684 E Page 18 Revision 1 0 This page is for your notes...
Page 50: ...CHAPTER 3 ND 70684 E Page 42 Revision 1 0 This page is for your notes...