Termination of Cables on MDF
STEP 3:
Connect the 25-pair cables on the MDF referring
shows the PFT connector pin assignment for each PFT circuit number
(No. 0 - No. 7).
Figure 007-35 PFT Connector Pin Assignment
PFT0
PFT0
26 Sta. T0 1 Sta. R0
27 4LC. T0 2 4LC. R0
28 C.O. T0 3 C.O. R0
29 4COT. T0 4 4COT. R0
30 Sta. T1 5 Sta. R1
31 4LC. T1 6 4LC. R1
32 C.O. T1 7 C.O. R1
33 4COT. T1 8 4COT. R1
34 Sta. T2 9 Sta. R2
35 4LC. T2 10 4LC. R2
36 C.O. T2 11 C.O. R2
37 4COT. T2 12 4COT. R2
38 Sta. T3 13 Sta. R3
39 4LC. T3 14 4LC. R3
40 C.O. T3 15 C.O. R3
41 4COT. T3 16 4COT. R3
42 Sta. T4 17 Sta. R4
43 4LC. T4 18 4LC. R4
44 C.O. T4 19 C.O. R4
45 4COT. T4 20 4COT. R4
46 Sta. T5 21 Sta. R5
47 4LC. T5 22 4LC. R5
48 C.O. T5 23 C.O. R5
49 4COT. T5 24 4COT. R5
50 25
PFT1
PZ-8PFTA
PFT1
26 Sta. T6 1 Sta. R6
27 4LC. T6 2 4LC. R6
28 C.O. T6 3 C.O. R6
29 4COT. T6 4 4COT. R6
30 Sta. T7 5 Sta. R7
31 4LC. T7 6 4LC. R7
32 C.O. T7 7 C.O. R7
33 4COT. T7 8 4COT. R7
34 9
35 10
36 11
37 12
38 13
39 14
40 15
41 16
42 17
43 18
44 19
45 20
46 21
47 22
48 23
49 E 24
50 –27V 25
No. 6
No. 7
Note
No. 0
No. 1
No. 3
No. 2
No. 5
No. 4
Note:
Pin 23 on PFT1 is MJ alarm input from LTC0 pin 25. This is also used when NEAX1000 is set up as