E-16 

3.

 

Driver/Firmware Setup 

 
The driver of this product is included “Starter Pack” of EXPRESS SERVER. “Starter Pack” is published on NEC 
web site. Starter Pack can be downloaded from NEC's support site. 
 
In addition, the driver may be temporarily released. Check the support information of this site and apply it as 
necessary. 
 
Firmware is also included in the Starter Pack, so please apply it as necessary. 
 
Support site URL: 

http://www.nec.com/express/ 

 
 

NOTE: 

 

To apply the driver / firmware, start Starter Pack and select the "Integrated installation" menu. 

 

Update the driver and firmware at the same time (recommended) 

 

Update the firmware with Starter Pack when adding boards or replacing them with maintenance parts. 

 

To update the firmware, start the SPP (Standard Program Package) on Starter Pack. 
Select and update according to the product model number of the line whose "type" column is "Firmware", 
refer to the following, 
N8104-178/179 : HPE Broadcom NX1 Online Firmware Upgrade Utility 
N8104-180/181 : HPE Intel Online Firmware Upgrade Utility 
N8104-209 : Intel Online Firmware Upgrade Utility 

 

The firmware update is applied to all the same type boards mounted on the server / the same series of chip 
mounting boards. 

 

If the firmware on the board is newer than that of Starter Pack, it will not be updated automatically. 
It is possible to forcibly downgrade. (Please activate the slide switch written as forced on the screen) 

 

After updating the firmware, turn the server AC power off and then on again. 

 

 

Summary of Contents for N8104-209

Page 1: ...izes Warranty 1 Only for using in Japan Safety and Compliance Guide 1 Note This warranty is available only for using in Japan Do not use it in any other than Japan N8104 178 1000BASE T 2ch Dual Port 1...

Page 2: ...i J 1 J 1 J 2 J 3 J 7 J 7 J 7 1 J 8 1 1 J 8 1 2 J 8 2 J 14 2 1 J 15 3 J 16 4 J 17 4 1 J 17 4 2 J 18 5 J 19 6 J 20 6 1 J 20 6 2 J 23...

Page 3: ...Conventions E 8 1 General Description E 8 1 1 Overview E 8 1 2 Description E 8 2 Hardware Installation Uninstallation E 14 2 1 Bracket Replacement E 15 3 Driver Installation Uninstallation E 16 4 Tro...

Page 4: ...ernet Xerox Corporation Intel Intel Corporation Broadcom Broadcom Limited Hewlett Packard Enterprise HPE Hewlett Packard Enterprise Development LP PCI Express PCI SIG 1 2 3 4 3 5 OS NEC Corporation 20...

Page 5: ...as without prior written permission 2 The contents of this guide are subject to change without prior notice 3 All efforts have been made to ensure the accuracy of all information in this guide If you...

Page 6: ...J 1 1 2 3 1 2 3 3...

Page 7: ...J 2...

Page 8: ...J 3 J 1 OFF OFF...

Page 9: ...J 4 6 2 J 23...

Page 10: ...J 5 OFF...

Page 11: ...J 6 1 OFF OFF 2 3 LAN LAN SG001...

Page 12: ...J 7 1000BASE T 3...

Page 13: ...SE T RJ 45 2 4 1Gbps PCI Express 1 2 LAN RJ 45 6 2 J 23 2 1 J 15 PCI Express PCI EXPRESS N8104 178 PCI Express 2 0 x1 x1 N8104 179 PCI Express 2 0 x4 x4 N8104 180 PCI Express 2 1 x4 x4 N8104 181 PCI E...

Page 14: ...J 9 N8104 178 PCI Express LAN PORT0 PORT1 0 1 ACT LINK PORT 0 PORT1 0 1 ACT LINK LINK 1Gbps 10 100Mbps ACT...

Page 15: ...J 10 N8104 179 PCI Express LAN PORT0 PORT1 PORT2 PORT3 ACT LINK PORT 0 PORT 1 PORT 2 PORT 3 LINK 1Gbps 10 100Mbps ACT...

Page 16: ...J 11 N8104 180 PCI Express LAN PORT A PORT B ACT LINK SPEED ACT LINK SPEED PORT A PORT B SPEED 1Gbps 10 100Mbps ACT LINK...

Page 17: ...J 12 N8104 181 PCI Express LAN PORT D PORT C PORT A PORT B ACT LINK SPEED PORT D PORT C PORT B PORT A SPEED 1Gbps 100Mbps 10Mbps ACT LINK...

Page 18: ...J 13 N8104 209 PCI Express LAN PORT A PORT B PORT D PORT C ACT LINK SPEED PORT A PORT B PORT C PORT D SPEED 1Gbps 100Mbps 10Mbps ACT LINK...

Page 19: ...J 14 2 OFF...

Page 20: ...J 15 2 1 1 2 3 N8104 178 N8104 179 N8104 180 181 209 LAN 1 LAN LAN 1 2...

Page 21: ...ck Starter Pack Starter Pack Starter Pack Standard Program Package SPP Type Firmware N8104 178 179 HPE Broadcom NX1 Online Firmware Upgrade Utility N8104 180 181 HPE Intel Online Firmware Upgrade Util...

Page 22: ...J 17 4 4 1 PCI Express PCI Express BIOS BIOS BIOS PCI Express Starter Pack SPP Standard Program Package SPP...

Page 23: ...J 18 4 2 6 2 J 23...

Page 24: ...J 19 5 1 2 UEFI PXE 3 Wake On LAN 4 5 System Configuration LAN Main Configuration Page F7 Defaults 6 SR IOV Single Root I O Virtualization...

Page 25: ...ress x1 Gen 2 RJ 45 Broadcom 5720 A0 55 9mm W 111 8mm L 51g 57g 12V 3 3VAUX 2 1W 2 2W 0 55 10 90 65 85 5 95 N8104 179 1000BASE T 4ch PCI Express 2 0 PCI Express 5GT s x4 Gen 2 LAN 10M 100M 1Gbps x4por...

Page 26: ...Express x4 Gen 2 RJ 45 Intel i350 68 6 W 134 6mm L 58g 64g 3 3V 3 3VAUX 4 1W 4 2W 0 55 10 95 40 85 5 95 N8104 181 1000BASE T 4ch PCI Express 2 1 PCI Express 5GT s x4 Gen 2 LAN 10M 100M 1Gbps x4port P...

Page 27: ...22 N8104 209 1000BASE T 4ch PCI Express 2 1 PCI Express 5GT s x4 Gen 2 LAN 10M 100M 1Gbps x4port PCI Express x4 Gen 2 RJ 45 Intel i350 68 6mm W 134 6mm L 81g 87g 3 3V 3 3VAUX 6W 0 55 10 90 65 85 5 95...

Page 28: ...J 23 6 2 LAN 10Base T 100Base TX 1000Base T RJ45 UTP STP 8 4 EIA TIA 10Base T 100Base TX 1000Base T Cat 3 Cat 5 Cat 5e 100m N8104 179 180 181 209 11 58 11 79mm 12mm 12mm...

Page 29: ...ay cause minor personal injury including burns or property damage if the instruction is ignored This guide uses the following three types of symbols to give indications and precautions against a dange...

Page 30: ...dicates a general precaution or warning that cannot be specifically identified Indicates that improper use may cause personal injury due to laser beam Indicates that improper use may cause personal in...

Page 31: ...y death or property damage if the product has been used in the above conditions Do not continue to use the equipment if you detect smoke odor or noise If the equipment emits smoke odor or noise immedi...

Page 32: ...e the equipment in the place where corrosive gases exist Make sure not to locate or use the equipment in the place where corrosive gases sulfur dioxide hydrogen sulfide nitrogen dioxide chlorine ammon...

Page 33: ...g any component Ground yourself to dissipate any static charge before handling the adapter To prevent any damage on components due to static electricity make sure to discharge static electricity from...

Page 34: ...any optional devices Wear a wrist strap on your wrist and provide earthing before starting work If no wrist strap is available discharge static electricity from your body by touching an unpainted met...

Page 35: ...ct to the network 1Gbps maximum per port IMPORTATANT Do not install this product to a computer that is not recommended by NEC Corporation NOTE Check the PCI Express slot which can be attached with ref...

Page 36: ...PORT0 PORT1 Screw 0 1 ACT LINK PORT 0 PORT1 0 1 Full Height Low Profile ACT LINK Description Lamp Lamp Status Meaning LINK On Green Link at 1000Mbps speed On Orange Link at 100Mbps or 10Mbps speed Off...

Page 37: ...T1 PORT2 PORT3 Heat sink Screw ACT LINK PORT 0 PORT 1 Full Height Low Profile PORT 2 PORT 3 Description Lamp Lamp Status Meaning LINK On Green Link at 1000Mbps speed On Orange Link at 100Mbps or 10Mbp...

Page 38: ...PORT B Screw ACT LINK SPEED ACT LINK SPEED PORT A PORT B Full Height Low Profile Description Lamp Lamp Status Meaning SPEED On Green Link at 1000Mbps speed On Orange Link at 100Mbps or 10Mbps speed O...

Page 39: ...ink Screw ACT LINK SPEED PORT D PORT C PORT B PORT A Full Height Low Profile Description Lamp Lamp Status Meaning SPEED On Orange Link at 1000Mbps speed On Green Link at 100Mbps speed Off Link at 10Mb...

Page 40: ...ink Screw ACT LINK SPEED PORT A PORT B PORT C PORT D Full Height Low Profile Description Lamp Lamp Status Meaning SPEED On Orange Link at 1000Mbps speed On Green Link at 100Mbps speed Off Link at 10Mb...

Page 41: ...round yourself to dissipate any static charge before handling the adapter To prevent any damage on components due to static electricity make sure to discharge static electricity from yourself before y...

Page 42: ...ed bracket and install the other bracket Please keep the removed bracket 3 Attach the bracket with the bracket fixing screw Memo When attaching detaching the bracket move the bracket in the direction...

Page 43: ...ck when adding boards or replacing them with maintenance parts To update the firmware start the SPP Standard Program Package on Starter Pack Select and update according to the product model number of...

Page 44: ...g the Latest BIOS Check the version of the system BIOS If the version is not proper Update the system BIOS to latest version Check the adapter Make sure the adapter is not broken Check the component o...

Page 45: ...e also 6 2 Network Cables page E 22 Make sure a tip of the cable is not dusty or not broken Check a tip of the cable If it has broken replace the cable If it is dirty or any dust sticks Remove the dus...

Page 46: ...ion guide of the server 2 PXE boot on UEFI is supported The 1st port only 3 Wake on LAN is not supported 4 PCI hot plug hot add hot remove and hot swap is not supported 5 Do not apply F7 Default in Ma...

Page 47: ...Typical 2 1W Max 2 2W Environment Operating Temp 0 to 55 C Humid 10 to 90 RH non condensing Storage Temp 65 to 85 C Humid 5 to 95 N8104 179 Dual Port 1000BASE T Adapter Interface internal PCI Express...

Page 48: ...lex x 4 port Connector internal PCI Express Gen 2 x4 lane external RJ 45 type Connector Controller Intel i350 Dimensions 68 6mm W 134 6mm L Weight 81g Low Profile Bracket attached 87g Full Height Brac...

Page 49: ...BASETX Cat 5 or better 1000BASE T Cat 5e or better Length 100 m max Limitation of N8104 179 180 181 209 Refer to the left figure which does not get used to use for the cable with boots with a connecto...