Troubleshooting 8-11
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0611
IDE configuration changed
Check IDE configuration.
0612
IDE configuration error - device disabled
0613
Com A configuration changed
Check COM A configuration.
0614
Com A config. error - device disabled
0615
Com B configuration changed
Check COM B configuration.
0616
Com B config. error - device disabled
0B22
CPUs are installed out of order.
Request the maintenance to replace the CPU.
0B28
Unsupported CPU detected on CPU Socket
1.
0B29
Unsupported CPU detected on CPU Socket
2.
Make sure that the server supports the CPU. If
you are not sure, contact your service
representative to request the maintenance.
0B42
Resource Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken off line.
0B5F
Forced to use Processor with error
Because an error is detected in CPU, the
system is forcibly started. Contact your service
representative.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
Contact your service representative.
0B6F
DIMM group with error is enabled.
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
0B71
System Temperature out of the range.
Contact your service representative to replace
the fan.
Summary of Contents for N8100-1417F
Page 16: ...x This page is intentionally left blank...
Page 36: ...2 8 General Description Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Page 143: ...Configuring Your Server 4 75 3 Setting menu for VD 0 is displayed...
Page 220: ...7 12 Maintenance This page is intentionally left blank...
Page 352: ...9 94 Upgrading Your Server This page is intentionally left blank...
Page 353: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 360: ...10 8 Internal Cabling Diagrams This page is intentionally left blank...
Page 362: ...A 2 Specifications This page is intentionally left blank...
Page 370: ...C 2 IRQ This page is intentionally left blank...
Page 426: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 430: ...G 4 Product Configuration Record Table This page is intentionally left blank...