
Upgrading Your Server 9-5
DEVICE INSTALLATION OR REMOVAL PROCEDURE
Install or remove a component from the server in the following procedure.
Hard Disk Drive
The server has three device bay slots to install hard disk drives with the SCA2 interface (Ultra 160
SCSI) in the disk bay of the front of the server.
IMPORTANT:
Do not use any hard disk drives that are not authorized by NEC.
Installing a third-party hard disk drive may cause a failure of the
server as well as the hard disk drive. Purchase hard disk drives of
the following models:
<SCSI hard disk drive>
– N8150-163F (73.2 GB, 10,000 rpm, Ultra 320)
– N8150-171F (146 GB, 10,000 rpm, Ultra 320)
– N8150-192 (300 GB, 10,000 rpm, Ultra 320)
– N8150-165F (36.3 GB, 15,000 rpm, Ultra 320)
– N8150-172F (73.2 GB, 15,000 rpm, Ultra 320)
– N8150-193 (146 GB, 15,000 rpm, Ultra 320)
<SATA hard disk drive>
– N8150-184 (80 GB, 7,200 rpm, serial ATA)
– N8150-185 (120 GB, 7,200 rpm, serial ATA)
– N8150-186 (250 GB, 7,200 rpm, serial ATA)
– N8150-204 (80 GB, 7,200 rpm, serial ATA2)
– N8150-205 (160 GB, 7,200 rpm, serial ATA2)
– N8150-206 (250 GB, 7,200 rpm, serial ATA2)
To make array configuration, specify RAID0, RAID1 or RAID5 as
the RAID level.
All drive slots may contain a hard disk drive approximately 25.4 mm (1 inch) high. The drive IDs
are always assigned to hard disk drives as shown below.
SCSI ID0
SCSI ID1
SCSI ID2
Channel 1
Channel 2
Not used.
Summary of Contents for N8100-1056F
Page 32: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Page 154: ...4 58 Configuring Your Server This page is intentionally left blank...
Page 236: ...6 26 Installing and Using Utilities This page is intentionally left blank...
Page 248: ...7 12 Maintenance This page is intentionally left blank...
Page 348: ...C 2 IRQ This page is intentionally left blank...
Page 408: ...G 4 Product Configuration Record Table This page is intentionally left blank...