REMOTE CONTROL ID FUNCTION

REMOTE CONTROL ID

The remote control can be used to control up to 100 individual MultiSync monitors using 
what is called the REMOTE CONTROL ID mode. The REMOTE CONTROL ID mode 
works in conjunction with the Monitor ID, allowing control of up to 100 individual MultiSync 
monitors. For example: if there are many monitors being used in the same area, a remote 
control in normal mode would send signals to every monitor at the same time (see 
Figure 1). Using the remote in REMOTE CONTROL ID mode will only operate one specifi c 
monitor within the group (see Figure 2).

TO SET REMOTE CONTROL ID

While holding down the REMOTE ID SET button on the remote control, use the KEYPAD to 
input the Monitor ID (1-100) of the display to be controlled via remote. The remote can then 
be used to operate the monitor having that specifi c Monitor ID number.
 When 0 is selected or when the remote control is in normal mode, all monitors will be 
operated.

TO SET/RESET REMOTE CONTROL MODE

ID Mode - To enter ID Mode press the REMOTE ID SET button and hold down for 
2 seconds.
 Normal Mode - To return to Normal Mode press the REMOTE ID CLEAR button and hold 
down for 2 seconds.

  In order for this feature to work properly, the display must be assigned a Monitor ID number. 

The Monitor ID number can be assigned under the MULTI DISPLAY menu in the OSD 
(See page 25).

  Point the remote control towards the remote sensor of the desired monitor and press the 

REMOTE ID SET button. The MONITOR ID number is shown on the display when your 
remote control is in ID mode.

Use the remote control to operate a monitor that has a specifi c MONITOR ID number assigned to it.

1. Set the MONITOR ID number for the display (See page 25). The MONITOR ID number can range from 1-100.

This MONITOR ID number allows the remote control to operate this specifi c monitor without affecting other monitors.

2. On the remote control, press and hold down the REMOTE ID SET button while using the keypad to input the REMOTE CONTROL ID number 

(1-100). The REMOTE ID NUMBER should match the MONITOR ID number of the display to be controlled. Choose “0” to simultaneously 
control all displays in range.

3. Point the remote control towards the remote sensor of the desired monitor and press the REMOTE ID SET button.

The MONITOR ID number is shown in red on the display.
If the REMOTE CONTROLID is “0”, then all displays in range will show their respective MONITOR ID number in red.

  If the MONITOR ID number is shown in white on the display, the MONITOR ID number and the REMOTE CONTROL ID are not the same.

This LCD monitor can be controlled via personal computer or wireless remote control using an RS-232C connection.

MONITOR ID and IR CONTROL

Using one PC or one infrared wireless controller, up to 100 individual LCD monitors can be controlled through a daisy chain via RS-232C 
connection.

1. Connect PC and LCD monitors.

  Connect a PC’s RS-232C control output to the LCD monitor RS-232C input. You can then connect the RS-232C output from the LCD monitor 

to another LCD monitor RS-232C input. Up to 100 monitors can be connected using RS-232C.

2. Set Monitor ID and IR Control mode.

  For proper operation, the Monitor ID should be set in the OSD menu of each monitor that is in the chain. The Monitor ID can be set under the 

“MULTI DISPLAY” menu in the OSD. The Monitor ID number can be set within a range from 1 to 100. No two monitors should share the same 
Monitor ID number. It is recommended to number each monitor in a daisy chain sequentially from 1. The fi rst monitor in the daisy chain is 
designated as the primary monitor. Subsequent monitors with the chain are secondary monitors.

  In the “ADVANCED OPTION” menu on the fi rst monitor in the RS-232C daisy chain set the “IR CONTROL” to “PRIMARY”.

  Set the “IR CONTROL” to “SECONDARY” on all other monitors.

Remote Control Function

Monitor ID:1

Monitor ID:2

Monitor ID:3

Monitor ID:1

Monitor ID:2

Monitor ID:3

Remote does 

not work

Remote does 

not work

Remote works

Remote works

Remote works

Remote works

Figure 1

Remote in 

Normal mode or 
the REMOTE ID 

is set to 0

Figure 2

Remote set up 

to use REMOTE 

ID:3

Summary of Contents for MultiSync V652-TM

Page 1: ...User s Manual MultiSync V652 TM...

Page 2: ...odel English 17 Basic Operation English 18 Power ON and OFF Modes English 18 Power Indicator English 19 Using Power Management English 19 Selecting a video source English 19 Picture Aspect English 19...

Page 3: ...erates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarante...

Page 4: ...erning the operation and maintenance of this unit has been included Therefore it should be read carefully in order to avoid any problems CAUTION CAUTION Please use the power cord provided with this mo...

Page 5: ...east once a year because of set reliability When using a LAN cable do not connect to a peripheral device with wiring that might have excessive voltage Do not use monitor under rapid temperature and hu...

Page 6: ...pe the cabinet with a soft cloth To clean the cabinet dampen the cloth with a neutral detergent and water wipe the cabinet and follow with a dry cloth NOTE DO NOT clean with benzene thinner alkaline d...

Page 7: ...le DVI D to DVI D cable Wireless Remote Control and AA Batteries Screw with washer M4 x 10 x 1 Clamp x 1 USB Cable Remember to save your original box and packing material to transport or ship the moni...

Page 8: ...structions included with the mounting equipment for detailed information Make sure there is no gap between the monitor and the bracket Installation Orientation When using the display in the portrait p...

Page 9: ...option boards Do not apply excessive force to manipulate the optional board before fixing it with screws Figure 1 3 Installing and removing optional table top stand CAUTION Installing and removing th...

Page 10: ...screws which are included with the optional table top stand Screw M4 Cord or chain Clamp 400 mm Screw Holes included in option stand Before attaching the LCD monitor to the wall make sure that the wal...

Page 11: ...the OSD menu is turned off Acts as EXIT button within the OSD to move to previous menu Remote control sensor and Power Indicator Receives the signal from the remote control when using the wireless rem...

Page 12: ...o input a composite video signal LAN port RJ 45 LAN connection See page 34 RS 232C D Sub 9 pin IN connector Connect RS 232C input from external equipment such as a PC in order to control RS 232C funct...

Page 13: ...English 11 English Internal speaker Kensington Lock For security and theft prevention BNC input signal...

Page 14: ...hen surround is set to ON KEYPAD Press buttons to set and change passwords change channel and set REMOTE ID ENT button 2 DISPLAY button Turns on off the information OSD See page 20 MENU button Turns o...

Page 15: ...Yes Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes DVD HD DVD HD Yes Yes Yes Yes Yes Yes No No Yes Yes No No No No Yes Yes No No No No SCART SCART Yes Yes Yes Yes Yes Yes No No Yes Yes No No No...

Page 16: ...LCD monitor so as not to scratch the panel 2 Install the remote control batteries The remote control is powered by two 1 5V AA batteries To install or replace batteries A Press and slide to open the c...

Page 17: ...8 Adjust the screen See pages 22 and 23 Make adjustments of the screen display position when necessary 9 Adjust the image See page 22 Make adjustments such as backlight or contrast when required 10 R...

Page 18: ...T Multiple monitors that are daisy chained have a limit to the connectable monitors Connected equipment Connecting terminal Setting in Terminal Mode Input signal name Connecting Audio terminal Input b...

Page 19: ...ly Connecting a Computer with DisplayPort Please use DisplayPort cable with DisplayPort compliance logo It may take a moment for the signal to appear Please note that DisplayPort connector does not su...

Page 20: ...while powered on and will turn red or amber while powered off NOTE The Main Power Switch must be in the ON position in order to power up the monitor using the remote control or the Power Button on th...

Page 21: ...en and Amber blink alternately Diagnosis Detecting failure Red Blinking See Troubleshooting page 39 1 If OFF is selected in POWER INDICATOR page 25 the LED will not light when the LCD monitor is in ac...

Page 22: ...s NOTE When picture mode is set to AMBIENT1 or AMBIENT2 BACKLIGHT AUTO BRIGHTNESS and BACKLIGHT in SCREEN SAVER function are disabled Do not cover Ambient light sensor when you use AMBIENT1 or AMBIENT...

Page 23: ...VIRONMENT CARBON FOOTPRINT 86 0 Input source Main Menu Icons Main Menu Item Sub Menu Key Guide Adjustment Settings Remote Control Press UP or DOWN button to select sub menu Press SET Press UP or DOWN...

Page 24: ...NATIVE except sRGB setting NATIVE Gamma correction is handled by the LCD panel 2 2 Typical display gamma for use with a PC 2 4 Good for video DVD etc S GAMMA Special gamma for certain types of movies...

Page 25: ...ADJUST menu back to factory setting AUTO ADJUST H POSITION V POSITION CLOCK PHASE H RESOLUTION V RESOLUTION ASPECT AUDIO VOLUME Increases or decreases output volume level 40 BALANCE Adjust the balanc...

Page 26: ...termines where the PIP appears on the screen X 95 Y 92 ASPECT Selects sub picture aspect FULL NORMAL and WIDE See page 19 FULL TEXT TICKER OFF MODE Enables Text Ticker and allows you to set Horizontal...

Page 27: ...ed remote control when using the RS 232C daisy chain NORMAL NORMAL The monitor will be controlled normally using the remote controller PRIMARY Choose PRIMARY for the first monitor within an RS 232C da...

Page 28: ...saving mode when an active signal is not present The monitor will automatically recover to ON state when a signal is reapplied POWER SAVE Sets how long the monitor waits to go into power save mode af...

Page 29: ...SCART VIDEO1 VIDEO2 or S VIDEO inputs will have priority over DVI VGA RGB HV When DVD HD SCART VIDEO1 VIDEO2 or S VIDEO input signal is present the monitor will change and keep to the DVD HD SCART VID...

Page 30: ...OWER is OFF a warning message appears when monitor power is turned off Note Warning message does not appear when monitor power is turned off by OFF TIMER setting or SCHEDULE setting OFF AUTO OFF Monit...

Page 31: ...mage remains visible on the screen Unlike CRT monitors LCD monitors image persistence is not permanent but constant images being displayed for a long period of time should be avoided To alleviate imag...

Page 32: ...le using the keypad to input the REMOTE CONTROL ID number 1 100 The REMOTE ID NUMBER should match the MONITOR ID number of the display to be controlled Choose 0 to simultaneously control all displays...

Page 33: ...ber of the monitor to be controlled To control the entire daisy chained monitors simultaneously select ALL as the Target ID 4 Use the wireless remote controller to control the SECONDARY monitor while...

Page 34: ...REPLY setting in EXTERNAL CONTROL In order to function the RS 232C OUT terminal can only be connected to another monitor of the same model Do not connect to other types of equipment To control monito...

Page 35: ...03 71 0d Input Source Select VGA 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 31 03 73 0d Input Source Select HDMI 01 30 41 30 45 30 41 02 30 30 36 30 30 30 31 31 03 72 0d Input Source Select DVD HD...

Page 36: ...ipt and Cookies and the browser should be set to accept these functions The setting method will vary depending on the version of browser Please refer to the help files and the other information provid...

Page 37: ...s or the entry column of the URL Example 2 When the IP address of the monitor is 192 168 73 1 access is gained to the mail alert settings by specifying http 192 168 73 1 index html for the address or...

Page 38: ...il transmission POP3 Server This specifies the address of the POP3 server that is used in the authentication of the e mail User Name This sets the user name for logging into the authentication server...

Page 39: ...re Abnormal Please contact your supplier A2h SENSOR reached at the temperature that the user had specified condition DISPLAY PROTECTION FAN CONTROL COOLING FAN AUTO Reconfirm the setting condition fro...

Page 40: ...use saving two thirds of your monitor energy costs reducing emissions and lowering the air conditioning costs of the workplace FullScan Capability Allows you to use the entire screen area in most reso...

Page 41: ...mode to non interlace and use 60Hz refresh rate Image of component signal is greenish Check to see if the DVD HD input connector is selected LED on monitor is not lit no green or red color can be see...

Page 42: ...ERNAL CONTROL The touch panel does not respond Make sure that PIP mode is not selected Check the input signal setting Make sure that STANDBY setting in TOUCH PANEL in ADVANCED OPTION is ON Make sure t...

Page 43: ...NTSC PAL60 Output Signal DVI DVI D 24pin Digital RGB DVI HDCP AUDIO AUDIO Input STEREO Mini Jack Analog Audio Stereo L R 0 5 Vrms HDMI Connector Digital Audio PCM 32 44 1 48 KHz 16 20 24bit DisplayPor...