NEC Display Solutions
Video Wall Installation Guide
PC-less display Self-Calibration
Through self-calibration, each monitor adjusts its settings according to
the factory calibrated LUT, managed by the inbuilt SpectraView engine.
PC-less calibration uses an MDSV Sensor 3 directly connected to the
dedicated monitor’s USB interface.
Connect the MDSV Sensor 3 to the display monitor’s USB1 (SENSOR)
interface.
Menu:
PICTURE
>
SPECTRAVIEW ENGINE
>
CALIBRATION
>
SET
STAND-ALONE CALIBRATION
>
SELF CALIBRATION
>
SET
Note:
For proper handling, this feature is recommended for video walls of
up to 3x3 displays, depending on accessibility. For most efficient handling,
larger video walls should be calibrated via the PC-based
Display
Wall
Calibrator
application.
PC-less White Copy function
Using the self-calibration feature, settings from a reference display are
copied to each dedicated display in the video wall. Connect a MDSV
Sensor 3 to the USB interface of the display to be adjusted. Using the
sensor, measure a white test pattern on the reference display to readjust
the display calibration.
Connect the MDSV Sensor 3 into the USB1 (SENSOR) interface of the
display to be adjusted.
Place the sensor on the reference monitor showing a white test pattern.
Menu:
PICTURE
>
SPECTRAVIEW ENGINE
>
CALIBRATION
>
SET
STAND-ALONE CALIBRATION
>
WHITE COPY
>
SET
Note:
To perform White Copy, self-calibration must be completed
beforehand. For proper handling, this feature is recommended for video
walls of up to 3x3 displays, depending on accessibility. For most efficient
handling, larger video walls should be calibrated via the PC-based
Display
Wall Calibrator
application.
In addition to the extensive calibration capabilities, two new high-end adjustment features lift the video wall calibration result to a new outstandingly high
level. For further details please refer to the
Display Wall Calibrator
application users manual.
Corner Uniformity Correction
To perform the corner colour matching on a single monitor.
Uniformity Correction
To perform internal screen uniformity on a display, up to 10x10
measurement points can be defined within one monitor.
Additional PC-less advanced calibration capabilities
Display Wall Calibrator application high-end adjustment capabilities
4
USB1 SENSOR