4-2
1. Application
This adjustment specification should be applied to the adjustment of the LCD1970NX (L194RJ).
2. Adjustment Conditions
2.1 Time for Adjustment
Adjustments should be made only when the unit is fully assembled.
2.2 Measuring Instruments, Jigs, and Tools
When adjusting the unit, use measurement instruments, jigs, and tools specified below.
a. Use a signal generator that can produce an all white, or all black screens. Signal timing should be
VG-819.
The amplitude of each signal (R, G, B) output should be maintained at 0.7Vp-p ± 0.05V when a load of 75
Ω
is connected.
2.3 Power Supply Voltage
INPUT: 100Vac ~ 240Vac
±
10%, 47~63Hz
2.4 Aging
Not required.