Input Panel 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC Control Codes 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function    

 

 

 

 

 

 

Code Data  

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER 

ON 

 

      02H 00H 00H 

 00H 

 00H 

 02H      

POWER 

OFF 

 

      02H 

 01H 

 00H 

 00H 

 00H 

 03H      

INPUT SELECT CCOMPUTER   

02H   03H  00H 

 00H 

 02H 

 01H 

 01H 

 09H   

INPUT SELECT VIDEO    

 

 

02H   03H  00H 

 00H 

 02H 

 01H 

 06H 

 0EH   

INPUT 

SELECT 

S-VIDEO 

 

   02H 

 03H   00H   00H   02H   01H   0BH   13H 

 

INPUT SELECT DVI (DIGITAL)   

02H 03H 00H 00H 02H 01H 1AH 22H  

PICTURE 

MUTE 

ON 

 

    02H 

 10H   00H   00H   00H   12H 

 

 

 

 

 

PICTURE 

MUTE 

OFF 

 

    02H 

 11H 

 00H 

 00H 

 00H 

 13H      

SOUND 

MUTE 

ON 

     02H 

 12H 

 00H 

 00H 

 00H 

 14H      

SOUND 

MUTE 

OFF 

 

    02H 

 13H   00H   00H 

00H   15H 

 

 

 

 

 

Note:

 

Contact your NEC rep for codes not listed.

 

 
 

Cable Connection 

Communication Protocol: 

Baud Rate:    

38400 bps (for cable lengths longer than 20’, it is recommended changing to 9600 bps in setup menu) 

 

 Data 

Length: 

 

 8 

bits 

Parity: 

   No 

Parity 

Stop 

Bit: 

  One 

Bit 

on/off:   None 

Communications: Full duplex 

                                                                                                                     

 

 

 
 

 

 

 
 
 
 

 
 
 
 
NOTE 1 :  
Pins 2, 3, 5, and 6 are used inside the projector. 
NOTE 2:   For long cable runs it is recommended to set communication speed within the projector to 9600 bps.   

1 2

3

4 5

6 7

8

9

To GND of PC

To RxD of PC

To TxD of PC

To CTS of PC

To RTS of PC

Summary of Contents for LT380 - MultiSync XGA LCD Projector

Page 1: ...n tables use the formulas below If the figures on the tables do not match the results of formulas use the figures in the table All calculations are based on 4 3 aspect ratio Distances are in inches for millimeters multiply by 25 4 Distances may vary 5 Formulas The Projection Formulas use the image width for calculation For proper projection placement determine the image width for the desired scree...

Page 2: ...ction tables use the formulas on page 1 Screen Size 4 3 Diag W H inches inches inches inches inches 30 24 18 6 3 60 48 36 13 5 72 57 6 43 2 16 6 84 67 2 50 4 18 7 90 72 54 19 8 100 80 60 22 9 120 96 72 26 10 150 120 90 32 13 180 144 108 39 15 200 160 120 43 17 250 200 150 54 21 300 240 180 65 25 B C wide tele D α wide tele inches degrees 33 41 9 0 11 1 69 84 8 7 10 6 83 102 8 7 10 5 98 119 8 7 10 ...

Page 3: ... 1 1 www necvisualsystems com LT380 Page 3 of 6 Cabinet Dimensions The following drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 Lens center Lens center 11 39 11 34 2 81 11 57 4 72 2 54 FOOT 2 30 boss 4 76 0 70 LENS MAX 0 78 LENS MIN 5 01 1 53 7 10 ventilation ...

Page 4: ...visualsystems com LT380 Page 4 of 6 Cabinet Dimensions continued The following drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 3 M4 8 max Lens center 2 85 6 85 1 83 3 60 7 28 0 98 for Ceiling Mount Lamp security slot ventilation ventilation 8 22 1 15 AC input Power Switch ...

Page 5: ...Guide Ceiling Mounted and Desktop Rev 1 1 www necvisualsystems com LT380 Page 5 of 6 Optional Ceiling Mount Dimensions Model VL80CM The following drawings show the ceiling mount dimensions Dimensions are in inches For millimeters multiply by 25 4 8 62 2 71 2 99 3 35 8 74 ...

Page 6: ...PICTURE MUTE ON 02H 10H 00H 00H 00H 12H PICTURE MUTE OFF 02H 11H 00H 00H 00H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H Note Contact your NEC rep for codes not listed Cable Connection Communication Protocol Baud Rate 38400 bps for cable lengths longer than 20 it is recommended changing to 9600 bps in setup menu Data Length 8 bits Parity No Parity Stop Bit One ...