background image

 037-4. LAMP INFORMATION REQUEST 3 
********************************************************************** 
Function: 
This command acquires the information on the projector lamp in Eco mode. 
 
Command: 
   03H  96H  00H  00H  02H  DATA01  DATA02  CKS 
                                             

 

 

(*3) 

 
   Data Portion Contents 
   ------------------------------------------------------------------- 
   DATA01    Target 
             00H : Lamp1 
             01H : Lamp2 
 
   DATA02    item 
               00H :  Lamp Hour Meter (second) (!) 

  01H :  Lamp usage time (second) (!!) 

               04H :  lamp remaining amount until lamp warning message  
                     (100% to -10%) 

  05H : Lamp counter (Normal mode) (second) (!!!) 

               06H : Lamp counter (Eco mode) (second) (!!!) 
               08H :  Remaining time until lamp warning message starts  
                     to appear (in terms of specified values) 
               09H :  Remaining time until lamp warning message starts  
                     to appear (in terms of Normal mode values) 
               0AH :  Remaining time until lamp warning message starts  
                     to appear (in terms of Eco mode values) 
               10H :  Remaining time until inhibition of lamp usage  
                     (in terms of specified values)                
 

  11H :  Remaining time until inhibition of lamp usage  

                     (in terms of Normal mode values) 
               12H :  Remaining time until inhibition of lamp usage  
                     (in terms of Eco mode values) 
 
Response: At the time of a success 
   23H  96H  01H  xxH  06H  DATA01 .. DATA06  CKS 
                    (*1)   (*2)                         

 

  (*3) 

 
   Data Portion Contents 
   ------------------------------------------------------------------- 
   DATA01        same values as DATA01 of the command 
   DATA02        same values as DATA02 of the command 
   DATA03 .. 06  Acquired information 
 
Response: At the time of a failure 
   A3H  96H  01H  xxH  02H  DATA01  DATA02  CKS 
                    (*1)     (*2)                     (*4)              (*3) 
 
Supplement: 
   * In case of acquiring lamp's use of hours 
    03H  96H  00H  00H  02H  00H  01H  9CH 
 
    Example of acquisition 
    DATA03  DATA04  DATA05  DATA06:  lamp's use of hours 
       50H     46H     00H     00H:  18000 seconds 
 
    Calculator Procedure 
    1) Set calculator to HEX 
    2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 
    3) Change from HEX to Decimal - value will change to 18000 seconds 
 

Summary of Contents for LT30 - XGA DLP Projector

Page 1: ...ies NP600 NP300 NP400 NP500 NP500W NP500WS NP600 NP600S Series VT VT770 Series VT70 VT37 VT47 VT480 VT57 VT570 VT575 VT670 VT676 Series VT80 VT48 VT480 VT580 Series VT90 VT49 VT490 VT590 VT595 VT695 Series VT700 VT700 WT WT600 WT610 WT615 Series NP4100 NP4100 NP4100W Series NP3250 NP1250 NP2250 NP3250 NP3250W Series NP610 NP310 NP410 NP410W NP510 NP510W NP510WS NP610 NP610S Series NP2200 NP1200 NP...

Page 2: ...using the USB port on the projector A USB cable is required 3 LAN connection 3 1 LAN connection using a wired LAN card A wired LAN card and LAN cable are required 3 2 LAN connection using a wireless LAN card A wireless LAN card is required 3 3 LAN connection using the LAN port on the projector A LAN cable is required 3 4 LAN connection using a wireless LAN unit A wireless LAN unit is required Stat...

Page 3: ...No No VT48 VT480 VT580 Yes No No No No No VT49 VT490 VT590 VT595 VT695 VT700 Yes No No No No No VT700 Yes No No No No No VT800 Yes No No No Yes No WT600WT 610 WT615 Yes Yes Yes Yes No No NP4000 NP4001 Yes No No No Yes No NP1250 NP2250 NP3250 NP3250W Yes No No No Yes Yes NP310 NP410 NP410W NP510 NP510W NP510WS NP610 NP610S Yes No No No Yes No NP1200 NP2200 Yes No No No Yes No NP4100 NP4100W Yes No ...

Page 4: ... Only the M300 series is compatible P350X P350W P420X Series STANDBY MODE POWER SAVING Control Command Serial port Wired LAN port Wireless LAN unit POWER ON Yes No No Yes Supported No Not supported 3 Interface Conditions Serial connection The communications method conforms to the RS 232C standard Baud rate 38400 bps NP600 series NP610 Series VT60 VT70 VT80 VT90 series VT700 19200bps Data length 8 ...

Page 5: ...ledge hereafter referred to as ACK that recognizes a command and Negative Acknowledge hereafter referred to as NAK that fails to recognize a command Command Controller Projector Response ACK or NAK 4 1 Frame Format One frame comprises a header a data portion and a checksum Frame Format Header portion Data portion Checksum Max 4095 Bytes 1 2 3 4 5 6 n m 8 8 8 4 12 8 8 8 Bit Bit Bit Bit Bit Bit Bit ...

Page 6: ... one basis Broadcast notification is recommended When the controller is connected with multiple projectors To control a certain projector use individual notification For all others broadcast notification is recommended Response This returns the projector ID for a projector received regardless of individual notification or broadcast notification CAUTION To notify individually specifying a model cod...

Page 7: ...Bit This is data length of data portion unit byte Command This sets data length of data added to a command to send it See each command description Response This sets data length of data added to a response to send it See each command description CAUTION Data length is specified using total of 12 bits 0 4095 of 4 bits of the 4th byte and 8 bits of the 5th byte The upper ranking 4 bits of the 4th by...

Page 8: ... compatible with the PC Viewer When a parameter error occurs 00H Unvalid values specified 01H Specified terminal is unavailable or cannot be selected 02H Selected language is not available When an operation mode error occurs 00H Available memory reservation error 01H External control working 02H Operating memory 03H Standby 04H On Forced on screen mute mode 05H Link mode working 06H Displaying a s...

Page 9: ...using a USB hub please use a self powered type not a bus powered type When using a USB hub connection to the first stage of the USB hub is recommended LAN connection Wired LAN port LAN interface Communication speed Auto setting 10 100Mbps Certified standard IEEE802 3 10BASE T IEEE802 3u 100BASE TX Auto Negotiation A LAN connector 8 male RJ 45 connector 1 TD Transmit data 2 TD Transmit data 3 RD Re...

Page 10: ... 03H B1H 00H 00H 02H 07H 00H BDH 046 WXGA MODE SETTING REQUEST 03H B0H 00H 00H 01H DATA1 CKS 049 WXGA MODE SETTING SET 03H B1H 00H 00H 02H DATA1 DATA2 CKS 050 REMOTE KEY CODE 02H 0FH 00H 00H 02H 00H 00H 13H 060 GAIN PARAMETER REQUEST 2 03H 04H 00H 00H 03H DATA CKS 077 MUTE CONTROL 02H 1AH 00H 00H 02H DATA CKS 078 1 SETTING REQUEST 00H 85H 00H 00H 01H 00H CKS 078 2 RUNNING STATUS REQUEST 00H 85H 00...

Page 11: ...3 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 006 RUNNING SENSE 007 COMMON DATA REQUEST 009 ERROR STATUS REQUEST 015 POWER ON 016 POWER OFF 018 INPUT SW CHANGE 020 PICTURE MUTE ON 021 PICTURE MUTE OFF 022 SOUND MUTE ON 023 SOUND MUTE OFF 024 ONSCREEN MUTE ON 025 ONSCREEN MUTE OFF 030 GAIN ADJUST 030 2 VOLUME ADJUST Volume Bass Treble Balance 030 12 IMAGE MODE ADJUST Aspect...

Page 12: ...H In case of NP60 series D0H In case of NP4000 4100 series 80H In case of NP905 NP901W VT800 90H 3 Checksum CKS inscription This is the value of the lower 8 bits of the results calculated in byte units from all of the data up to the immediately preceding data Example 20H 81H 01H 60H 01H 00H 03H CKS 4 Response error number This is the value of the error number at the time of an error See NAK of 6 2...

Page 13: ...1 During execution Bit 6 Selecting signal processing 0 No execution Normal condition 1 During execution Bit 5 Cooling processing 0 No execution Normal condition 1 During execution Bit 4 External control mode 0 OFF 1 ON Bit 3 No Power Off period 0 Power Off Possible Normal condition 1 Power Off Impossible Bit 2 Reserved Bit 1 Projector status 0 Idling 1 Power On Bit 0 Reserved Response At the time ...

Page 14: ... During execution DATA06 Indication signal number Entry list number 1 0 199 DATA07 Type 1 of input terminal to be selected 1 01H 1 02H 2 03H 3 04H 4 05H 5 DATA08 Type 2 of input terminal to be selected 1 01H RGB 5 02H VIDEO 03H S VIDEO 04H COMPONENT 05H Reserved 06H DIGITAL 6 07H VIEWER 08H SLOT1 09H SLOT2 DATA09 Indication signal type Valid only when Type 2 of input terminal is 02H or 03H x0H NTS...

Page 15: ... LT180 LT80 HT GT WT VT NP1000 NP3150 NP905 NP4000 NP4100 NP62 NP64 NP3250 NP216 02H Cross Hatch x x x x x x 03H Gray Bars x x x x X 04H Raster 0 05H Raster 25 x x 06H Raster 50 x x 07H Raster 100 08H Focus x x x x x x x x 09H Raster Blue x x x x 0AH Gray Raster 30 17H Gray Raster 10 18H RAMP WBRG x x x x x x x x x x 19H Blue Raster 60 x x x x x x x x 1DH Cross Hatch 3 1 x x x x x x x x x Supporte...

Page 16: ...ying DATA68 Selecting signal processing 00H No execution Normal condition 01H During execution DATA69 Status of operation 00H Idling 04H Power On 05H Cooling 06H Idling Error occurrence Other than above nondisclosure Internal use of code during a state transition period DATA70 71 Projector type ...

Page 17: ... 10H 00H 08H VT700 10H 00H 09H NP600 10H 01H 09H NP500 10H 02H 09H NP500 W 10H 03H 09H NP400 10H 04H 09H NP300 10H 00H 10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310 10H 07H 10H NP610S 10H 08H 10H NP510WS 10H 09H 10H NP410 10H 01H 11H NP2200 10H 02H 11H NP1200 11H 00H 00H NP41 61 11H 01H 00H NP62 11H 00H 11H NP215 11H 02H 11H NP115 11H 03H 11H NP110 11H 04H 11H ...

Page 18: ...of a failure A0H C0H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 1 VT700 NP600 series Selected input terminal Data 07 Data08 RGB or RGB1 5 1 01H RGB 01H RGB2 5 2 02H RGB 01H Video 1 01H VIDEO 02H S Video 1 01H S VIDEO 03H Component 2 02H COMPONENT 04H Component 3 03H COMPONENT 04H DVI or DVI Digital 6 1 01H DIGITAL 06H HDMI 1 01H DIGITAL 06H Viewer 1 01H VIEWER 07H LAN 2 02H VIEWER 07H Slot1 1 1 01H SLO...

Page 19: ...life DATA02 Error Status 2 bit0 Lamp or Lamp1 has been used beyond its limit bit1 Formatter error bit2 Lamp2 error bit3 None bit4 None bit5 None bit6 None bit7 None DATA03 Error Status 3 bit0 None bit1 FPGA error bit2 Temperature error Sensor bit3 Lamp or Lamp1 housing error bit4 Lamp or Lamp1 data error bit5 Mirror cover error bit6 Lamp2 has reached its end of life bit7 Lamp2 has been used beyond...

Page 20: ... OFF Function This command switches off the main power of the projector Command 02H 01H 00H 00H 00H 03H Response At the time of a success 22H 01H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement The projector doesn t accept the other command during power off processing It contains a cooling period 018 INPUT SW CHANGE Function This com...

Page 21: ...60 LT280 does not support a DVI connector HT1000 HT410 HT510 HT1100 VT770 support Component and Viewer 1 VT470 VT470JY VT570 VT670 VT575 VT676 VT480 VT580 2 VT595 VT695 VT700 NP300 NP400 NP500 NP500W NP600 NP500WS NP600S 3 NP62 NP64 only not available on NP41 NP43 NP61 Terminal Name Terminal Number Response At the time of a success 22H 03H 01H xxH 01H DATA01 CKS 1 2 3 Data Portion Contents DATA01 ...

Page 22: ... 2 4 3 022 SOUND MUTE ON Function This command mutes the sound Command 02H 12H 00H 00H 00H 14H Response At the time of a success 22H 12H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 12H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Sound mute is cancelled for the following Input connector switching Video signal switching Volume adjustment 023 SOUND MUTE OFF Function This command ...

Page 23: ...switching 025 ONSCREEN MUTE OFF Function This command cancels the blanking of the on screen display Command 02H 15H 00H 00H 00H 17H Response At the time of a success 22H 15H 01H xxH 00H CKS 1 2 3 Response At the time of a failure A2H 15H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 030 GAIN ADJUST direct setting of volume volume increment decrement direct setting of brightness brightness increment decrem...

Page 24: ...me 00H Volume only DATA03 00H direct settings 01H increment decrement DATA04 lower data 8bit DATA05 upper data 8bit ex 1 volume direct setting value 20 DATA01 05H Volume DATA02 00H Volume only DATA03 00H direct setting DATA04 14H lower data 20 0014 Hex DATA05 00H upper data 20 0014 Hex ex 2 brightness increment value 1 DATA01 00H Brightness DATA02 FFH except Volume DATA03 01H increment decrement D...

Page 25: ...01 DATA02 CKS 1 2 3 Data Portion Contents DATA01 02 Results 0000H Normal 0000H Other Error Response At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Command example Setting Volume to 10 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030 12 IMAGE MODE ADJUST Function This command adjusts the Image Mode Command 03H 10H 00H 00H 05H DATA01 DATA05 CKS 3 Data Portion Contents DATA01 0...

Page 26: ... 00H Aspect Ratio 1 78 1 16 9 02H 00H Aspect Ratio Cinema 16 9 NP600 NP610 NP2200 NP62 NP64 NP215 P420 Series 02H 00H Aspect Ratio Crop 03H 00H Aspect Ratio Wide Zoom NP4000 Series NP4100 Series 03H 00H Aspect Ratio Native NP600 NP610 NP2200 NP62 NP64 NP216 P420 Series 03H 00H Aspect Ratio 1 85 1 03H 00H Aspect Ratio Zoom 03H 00H Aspect Ratio 4 3 Fill 04H 00H Aspect Ratio 4 3 NP600 P420 Series 04H...

Page 27: ...tion Examples DATA83 DATA84 DATA85 DATA86 Lamp Timer 00H 00H 00H 00H Total 0 seconds C0H 65H 52H 00H Total 5400000 seconds 3600 1500 hours 00H E4H 57H 00H Total 5760000 seconds 3600 1600 hours Calculator Procedure 1 Set calculator to HEX 2 Punch in DATA86 DATA85 DATA84 DATA83 005265C0 3 Change from HEX to Decimal value will change to 5400000 seconds The projector s hours of use is displayed in ter...

Page 28: ...conds Starting time for lamp usage warning message in terms of Normal mode values DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H 7200000 second Calculator Procedure 1 Set calculator to HEX 2 Punch in DATA12 DATA11 DATA10 DATA09 006DDD00 3 Change from HEX to Decimal value will change to 7200000 seconds Lamp remaining time in terms of Normal mode values 7200000 10800 3600 1997 hour 037 2 LAMP INFORMATI...

Page 29: ... values 10H Remaining time until inhibition of lamp usage in terms of specified values 11H Remaining time until inhibition of lamp usage in terms of Normal mode values 12H Remaining time until inhibition of lamp usage in terms of Eco mode values Response At the time of a success 23H 96H 01H xxH 06H DATA01 DATA06 CKS 1 2 3 Data Portion Contents DATA01 same values as DATA01 of the command DATA02 sam...

Page 30: ...T 4 Function This command acquires the information on the projector lamp Command 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS 3 Data Portion Contents DATA01 Target 00H Lamp1 01H Lamp2 DATA02 Unit 4 00H Second 01H Reserved 02H Hour DATA03 Item 00H Lamp Hour Meter second 2 01H Lamp usage time second 3 04H lamp remaining amount until lamp warning message 100 to X 1 05H Lamp usage time Normal mode sec...

Page 31: ...Time 100 Lamp Use Warning Starting Time Example The case of Lamp Use Prohibited Time 2100 H A Lamp Use Warning Starting Time 2000 H Model X 100 2100 100 2000 5 2 Lamp Hour Meter This is the timer for normal lamp mode conversion 3 Lamp usage time This is the lamp total usage It is displayed in the projector s menu 4 This setting is ignored if the Item s unit is not time 5 NP4000 4001 NP4100 4100W T...

Page 32: ...TA01 07H fixed DATA02 Results 00H Normal 01H Error Response At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 046 WXGA MODE SETTING REQUEST Function This command acquires the setting of the WXGA Mode of projector Command 03H B0H 00H 00H 01H C3H 77H Response At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS 1 2 3 Data Portion Contents DATA01 C3H fixed DATA02 Settin...

Page 33: ...rmal 01H Error Response At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 6 Response At the time of a success ACK This returns ACK without adding data portion to the command that does not request data This returns ACK with adding data to the data portion for the command that requests data At the time of a failure NAK This adds a cause of not accepting the command to data porti...

Page 34: ...ote control key code Word type Key number DATA01 DATA02 Key name 1 01H 00H POWER 2 02H 00H POWER ON 3 03H 00H POWER OFF 4 04H 00H SOURCE AUTO 5 05H 00H AUTO 6 06H 00H MENU 7 07H 00H UP 8 08H 00H DOWN 9 09H 00H RIGHT 10 0AH 00H LEFT 11 0BH 00H ENTER 12 0CH 00H CANCEL 13 0DH 00H HELP 14 0EH 00H POINTER 15 0FH 00H MAGNIFY UP 16 10H 00H MAGNIFY DOWN 17 11H 00H PICTURE MUTE 18 12H 00H SOUND MUTE 19 13H...

Page 35: ...H DIGITAL1 84 54H 00H DIGITAL2 85 55H 00H PC CARD 96 60H 00H BS 132 84H 00H VOLUME UP 133 85H 00H VOLUME DOWN 134 86H 00H KEYSTONE UP 135 87H 00H KEYSTONE DOWN 136 88H 00H SLIDE UP 137 89H 00H SLIDE DOWN 138 8AH 00H FREEZE 158 9EH 00H FILE 159 9FH 00H PAGE 163 A3H 00H ASPECT 164 A4H 00H VIDEO3 165 A5H 00H VIDEO4 166 A6H 00H S VIDEO3 167 A7H 00H S VIDEO4 200 C8H 00H ZOOM 201 C9H 00H FOCUS 214 D6H 0...

Page 36: ...0 series and NP4000 series VT60 series VT70 series VT80 series and VT90 series Command example Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H Sending the AUTO SHORT key code 02H 0FH 00H 00H 02H DDH 00H F0H cycle toggle volume mute cycle toggle picture mute cycle toggle picture freeze 02H 0FH 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents DATA01 DATA02 12H 00H Volume mute DATA01 DAT...

Page 37: ... Data Portion Contents DATA01 Same as DATA01 of the transmit data DATA02 to 05 Carbon Savings Kilogram Maximum 99999 kg DATA06 to 09 Carbon Savings Milligram Maximum 999999 mg Response At the time of a failure A3H 9AH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Example for Total Carbon Savings DATA02 DATA03 DATA04 DATA05 Kilogram 9CH 09H 00H 00H 2460 kg DATA06 DATA07 DATA08 DATA09 Milligram 0...

Page 38: ...justment possible FFH Selected gain is not available DATA02 Maximum adjustment value Lower ranking 8 bits DATA03 Maximum adjustment value Upper ranking 8 bits DATA04 Minimum adjustment value Lower ranking 8 bits DATA05 Minimum adjustment value Upper ranking 8 bits DATA06 Default adjustment value Lower ranking 8 bits DATA07 Default adjustment value Upper ranking 8 bits DATA08 Current value Lower ra...

Page 39: ... Black Correct Position 2CH 01H Black Correct Gain 2CH 02H Black Correct Inv Gain 2DH 00H Lamp Output 2EH 00H Signal Level Auto Control 2FH 00H Signal Level R G B Gain R 2FH 01H Signal Level R G B Gain G 2FH 02H Signal Level R G B Gain B 30H 00H Signal Level Y Cb Cr Gain Y 30H 01H Signal Level Y Cb Cr Gain Cb 30H 02H Signal Level Y Cb Cr Gain Cr 31H 00H Signal Level Y Pb Pr Gain Y 31H 01H Signal L...

Page 40: ...nce 62H 00H Digital Zoom Zoom 62H 01H Digital Zoom Horizontal Position 62H 02H Digital Zoom Vertical Position 63H 00H White Bal Dual Brightness R 63H 01H White Bal Dual Brightness G 63H 02H White Bal Dual Brightness B 63H 03H White Bal Dual Contrast R 63H 04H White Bal Dual Contrast G 63H 05H White Bal Dual Contrast B 64H 00H White Bal Lamp1 Brightness R 64H 01H White Bal Lamp1 Brightness G 64H 02...

Page 41: ... 2 3 Data Portion Contents DATA01 Results 00H Normal 01H Error Response At the time of a failure A2H 1AH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 Supplement Sound mute is cancelled in the following cases Input connector switching Video signal switching Volume adjustment 078 1 SETTING REQUEST Function This command acquires the function information of projector Command 00H 85H 00H 00H 01H 00H 86H Respo...

Page 42: ...0 10H 01H 09H NP500 10H 02H 09H NP500 W 10H 03H 09H NP400 10H 04H 09H NP300 10H 00H 10H NP610 10H 01H 10H NP510 10H 02H 10H NP510W 10H 03H 10H NP410 10H 05H 10H NP310 10H 07H 10H NP610S 10H 08H 10H NP510WS 10H 09H 10H NP410 10H 01H 11H NP2200 10H 02H 11H NP1200 11H 00H 00H NP41 61 11H 01H 00H NP62 11H 00H 11H NP215 11H 02H 11H NP1150 NP2150 NP3150 11H 02H 11H NP115 11H 03H 11H NP110 11H 04H 11H NP...

Page 43: ...onse At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 02 Reserved DATA03 Projector status 00H Idling 01H Power On DATA04 Cooling processing 00H No execution Normal condition 01H During execution DATA05 Power On Off processing 00H No execution Normal condition 01H During execution DATA06 Status of operation 00H Idling 04H Power On 05H Cooling 06H Idl...

Page 44: ...ntents DATA01 Selecting signal processing 00H No execution Normal condition 01H During execution DATA02 Signal number Entry list number 1 0 199 DATA03 04 Selected input terminal Terminal name DATA03 DATA04 RGB1 RGB 5 01H 01H RGB2 5 02H 01H DVI Analog 02H 01H Video 01H 02H S Video 01H 03H Component 02H 04H Component 03H 04H DVI 6 01H 06H DVI DIGITAL 6 01H 06H HDMI 01H 06H Viewer 01H 07H LAN 02H 07H...

Page 45: ... 078 4 MUTE STATUS REQUEST Function This command acquires the status of the mute of projector Command 00H 85H 00H 00H 01H 03H 89H Response At the time of a success 20H 85H 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 Picture mute 00H OFF 01H ON DATA02 Sound mute 00H OFF 01H ON DATA03 On screen mute 00H OFF 01H ON DATA04 Forced on screen mute 00H OFF 01H ON DATA05 On screen disp...

Page 46: ... not available 02H 00H Available memory reservation error 02H 02H Operating memory 02H 03H Setting not possible 02H 04H On Forced on screen mute mode 02H 06H 02H 07H No signal 02H 08H 02H 09H No PC card is inserted 02H 0AH Memory operation failed 02H 0CH Displaying the Entry List 02H 0DH Power Off inhibited 02H 0EH Execution error 02H 0FH No operation authority 03H 00H Specified gain number is wro...

Page 47: ... 98H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 097 196 WXGA MODE SETTING REQUEST Function This command acquires the setting of the WXGA Mode of projector Command 03H B0H 00H 00H 01H C3H 77H Response At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS 1 2 3 Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H OFF 01H ON Response At the time of a failure A3H B0H 01H xxH 02H DATA01 ...

Page 48: ...DE BY SIDE if DATA02 is POSITION 01H 00H TOP LEFT 01H TOP RIGHT 02H BOTTOM LEFT 03H BOTTOM RIGHT if DATA02 is SOURCE 02H 00H OFF 01H VIDEO 02H S VIDEO Response At the time of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 098 198 PIP SIDE BY SIDE SET Function This command sets the PIP SIDE BY SIDE of projector Command 03H B1H 00H 00H 03H DATA01 DATA02 DATA03 CKS Data Portion Contents DATA...

Page 49: ... A3H B1H 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 110 AUTO FUNCTIONS EXECUTE Function This command executes the auto functions Command 03H B6H 00H 00H 01H DATA01 CKS 3 Data Portion Contents DATA01 Execution items Focus 00H 01H According to projector setting Executing Response At the time of a success 23H B6H 01H xxH 02H DATA01 DATA02 CKS 1 2 3 Data Portion Contents DATA01 Execution items Same as DATA...

Page 50: ...ailure A3H BAH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 305 1 BASE MODEL TYPE REQUEST Function This command acquires the projector type Command 00H BFH 00H 00H 01H 00H C0H Response At the time of a success 20H BFH 01H xxH 10H DATA01 DATA16 CKS 1 2 3 Data Portion Contents DATA01 00H fixed DATA02 03 Projector type See DATA13 14 DATA04 12 Model name NULL termination character string DATA13 14 Projector ...

Page 51: ... 03H 08H 01H 10H NP4100W 01H 10H 00H 08H VT700 FFH 10H 00H 09H NP600 FFH 10H 01H 09H NP500 FFH 10H 02H 09H NP500W FFH 10H 03H 09H NP400 FFH 10H 04H 09H NP300 FFH 10H 00H 10H NP610 FFH 10H 01H 10H NP510 FFH 10H 02H 10H NP510W FFH 10H 03H 10H NP410 FFH 10H 05H 10H NP310 FFH 10H 07H 10H NP610S FFH 10H 08H 10H NP510WS FFH 10H 09H 10H NP410 FFH 10H 01H 11H NP2200 FFH 10H 02H 11H NP1200 FFH 11H 00H 00H ...

Page 52: ...H Idle 04H Power On 05H Cooling 06H Idle Error Standby Other Not Support Other than above nondisclosure Internal use of code during a state transition period DATA03 Indicate Contents 00H Picture signal displaying 01H No Signal 02H Viewer displaying 03H Test Pattern displaying 04H LAN displaying 05H Test Pattern User displaying 10H Signal selection in progress Other Not Support DATA04 Select source...

Page 53: ...nput Other Not Support DATA07 Picture Mute 00H OFF 01H ON DATA08 Sound Mute 00H OFF 01H ON DATA09 On screen mute 00H OFF 01H ON DATA10 DATA16 Reserved Response At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 CKS 1 2 4 3 6 1 Response At the time of a success ACK This returns ACK without adding data portion to the command that does not request data This returns ACK with adding data to the...

Page 54: ...sible 02H 04H On Forced on screen mute mode 02H 07H No signal 02H 08H 02H 0AH Memory operation failed 02H 0DH Power Off inhibited 02H 0EH Execution error 02H 0FH No operation authority 03H 00H Specified gain number is wrong 03H 01H Selected gain is not available 03H 02H Adjustment failed Error types Error contents The current model does not support this function Specified terminal is unavailable o...

Reviews: