CHAPTER 3 INSTALLATION
User’s Manual U14139EJ1V0UM00
14
3.3 Connecting the Target System and IE-77016-CM-LC
3.3.1 In the case of the
µµµµ
PD77016 Family (except
µµµµ
PD77016)
Connect the IE-77016-CM-LC to the target system using the 10-pin flat cable supplied with the IE-77016-CM-LC.
First connect the 14-pin connector of the flat cable to the J1 connector of the IE-77016-CM-LC. Then connect the
10-pin connector to the pin provided on the target system side (Refer to APPENDIX TARGET SYSTEM PINS).
3.3.2 In the case of the
µµµµ
PD77111 Family
Connect the IE-77016-CM-LC to the target system using the 12-pin (or 14-pin) flat cable supplied with the IE-
77016-CM-LC.
First connect the 14-pin connector of the flat cable to the J1 connector of the IE-77016-CM-LC. Then connect the
12-pin (or 14-pin) connector to the pin provided on the target system side (Refer to APPENDIX TARGET SYSTEM
PINS).
Remark Connector pins with 14-pin specifications are recommended for the target system side. In the case of
the supplied flat cables, the 14-pin flat cable is recommended over the 12-pin flat cable due to its higher
strength.
If connecting a connector pin with 12-pin specifications to the target system, the 14-pin flat cable can be
used, if enough space is left when positioning components around the connector pin so that the flat
cable connector does not interfere with the components on the target device. In this case, since there
are no signals for the 2 extra pins of the 14-pin flat cable, no special handling is required for these 2
pins.
Figure 3-1. Connecting Target System and IE-77016-CM-LC
10/12/14-pin flat cable (included with IE-77016-CM-LC)
To IE-77016-CM-LC J1
Target system