CHAPTER 3 INSTALLATION
User’s Manual U15928EJ1V0UM
24
<2> Prepare the IE-178048-NS-EM1.
<3> Remove the crystal oscillator that is mounted in the IE-178048-NS-EM1’s socket (the socket
marked as mainCLK).
<4> Connect the parts board (from <1> above) to the socket (mainCLK) from which the crystal oscillator
was removed (in <3> above). Check the pin 1 mark to make sure the board is mounted in the
correct direction.
<5> Make sure that the parts board mounted in the mainCLK socket on the emulation board is wired as
shown in Figure 3-7 above.
<6> Connect the IE-178048-NS-EM1 to the IE-78K0-NS or IE-78K0-NS-A.
The above steps configure the following circuit and enable supply of the clock from the mounted resonator to the
emulation device.
1 M
Ω
11
4
3
12
CA
CB
13
2
5
10
Rx
9
8
6
HCU04
HCU04
X
VHC157
A
Y
B
HKS120
X1
LV
CC
X1
IE-78K0-NS or IE-78K0-NS-A side
(Emulation device)
1 M
Ω
Remark
The sections enclosed in broken lines indicate parts that are attached to the parts board.