CHAPTER 3 INSTALLATION
User’s Manual U15928EJ1V0UM
18
3.1
Connection
(1) Connection with IE-78K0-NS or IE-78K0-NS-A main unit
See
IE-78K0-NS User’s Manual (U13731E)
for a description of how to connect the IE-178048-NS-EM1 to the IE-
78K0-NS. See
IE-78K0-NS-A User’s Manual (U14889E)
for a description of how to connect the IE-178048-NS-
EM1 to the IE-78K0-NS-A.
(2) Connection with 178048 PROBE Board
When using the emulation probe NP-80GK, use the 178048 PROBE Board. Connect CN5 of the IE-178048-NS-
EM1 and CN1 of the 178048 PROBE Board, aligning pin 1 of each.
(3) Connection with emulation probe
See the manual of the in-circuit emulator to be used (
IE-78K0-NS User’s Manual (U13731E)
or
IE-78K0-NS-A
User’s Manual (U14889E)
) for a description of how to connect the emulation probe to the IE-178048-NS-EM1.
When using the emulation probe NP-64CW, connect it to CN5 on this board. When using the emulation probe
NP-80GK, connect it to CN2 on the 178048 PROBE Board.
(4) Connection with BNC PROBE
Connect the supplied BNC PROBE to the J1 to J8 connectors on the IE-178048-NS-EM1.
Signals corresponding to J1 to J8 are as follows. Connect to amplify inputs from the target system.
J1: VSYNC
J5: B
J2: HSYNC
J6: I
J3: R
J7: Open (not connected)
J4: G
J8: BLANK
Caution
Incorrect connection methods may damage the IE system.
Be sure to read the emulation probe’s user’s manual for a detailed description of the correct