![NEC Express5800/R110j-1 System Configuration Manual Download Page 30](http://html.mh-extra.com/html/nec/express5800-r110j-1/express5800-r110j-1_system-configuration-manual_251282030.webp)
SYSTEM CONFIGRATION GUIDE –
NEC Express5800/R110j-1
NEC Corporation
Revision 1.0
– January 2019
30
Internal
drive supplementary matters
Conditions of Internal Drives in the default factory configuration
In BTO configuration, there are some conditions of drive types and RAID levels can be installed as below.
Common
All drives in BTO shipment should be of the same type, sector and rotation speed.
For the shipment with RAID array, arrange the drives in the same capacity as many as needed.
RAID controller configuration
RAID level 0, 1, 5, 6, 10 can be installed for BTO shipment. Selectable RAID levels are depending on the RAID controller.
Capacity of Logical drive can be within 2TB with legacy boot mode, capacity of logical drive can be within the total capacity of
logical disks with UEFI boot mode.
As factory shipment, Initial cache policy of RAID controllers is Write Through for N8103-192, Write back for N8103-193.
RAID configuration for shipment
RAID configuration for
shipment
Number of Drives
Number of Drives in RAID levels
Non RAID
1~6
Non
Embedded RAID
configuration (RAID 0/1/10)
1
RAID0(Single drive)
2
RAID1
3
2 in RAID1
、
1 for hotspare
4/6
4/6 in RAID10
5
4 in RAID10, 1 for a hotspare
RAID controller
configuration(RAID 0/1/10)
1
RAID0(Single drive)
2
RAID1
3
2 in RAID1, 1 for a hotspare
4/6
4/6 in RAID10
5
4 in RAID10, 1 for a hotspare
RAID controller configuration
(RAID 0/1/5/6/10)
1
RAID0(Single drive)
2
RAID1
3~6
RAID5
Conditions for mixing of Internal Drives after shipment
RAID controller is required for mixing of Internal Drives
Mixed Internal Drives cannot be installed in the same RAID array.
When using hotspare disk for different RAID arrays which consist of various type of drives, assign “Dedicated Hot Spare” to
each RAID arrays with the same type of drive, to prevent from mixing different type of drives in a RAID array. “Global Hot Spare”
cannot be used.
Mixing of different type of drives
Two types of drive can be installed in standard drive cage (4slots) and optional drive cage (2slots). Same type between different
drive cages is not necessary.
There is 11
“
type
”
, such as SAS HDD 10,000rpm(512n)
、
SAS HDD 10,000rpm(512e)
、
SAS HDD 15,000rpm(512n)
、
SAS HDD
15,000rpm(512e)
、
SATA HDD 7,200rpm(512n)
、
SATA HDD 7,200rpm(512e)
、
SATA SSD(VE/RI)
、
SAS SSD(ME/VE/RI).