NEC Express5800/R110j-1 System Configuration Manual Download Page 23

SYSTEM CONFIGRATION GUIDE – 

NEC Express5800/R110j-1

 

NEC Corporation 

Revision 1.0 

– January 2019 

23 

 

R110j-1 does not have management LAN port nor serial port as standard. Please order Management Lan with Serial Kit(N8117-
12) if you need those ports. 

Add-on Components 

9.1 

17-inch LCD Console Drawer 

Category 

Product Name / Description 

Part Number 

Drawer 
w/    KVM 

Drawer 

17-inch LCD Console Drawer (8 port) 

17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM 
switch, 1U height 

N8143-106F 

 

Cable 

Switch Unit Connection Cable Set (USB, 1.8m) 

1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(1A) 

 

 

Switch Unit Connection Cable Set (USB, 3m) 

3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(03) 

 

 

Switch Unit Connection Cable Set (USB, 5m) 

5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(05) 

Drawer 
w/o KVM 

Drawer 

17inch LCD Console Unit 1U 

17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-
pin mini D-sub VGA cable 2 m 

N8143-105F 

 

17inch LCD Console Drawer (1 port) 

17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-
button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 
cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m 

N8143-108F 

 

17.3inch LCD Console Drawer (1port) 

17.3-inch wide Full HD LCD, US 103-keys Keyboard with 10-key, 
Touch 
pad with 2-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, 
15-pin mini D-sub VGA cable 1.8 m, DVI-D cable 1.8m 

N8143-122F 

 

Keypad 

Keyboard Unit (JP) 

JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD 
Console Drawer (1 port) 

N8143-109 

 

 

Keyboard Unit (UK) 

UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD 
Console Drawer (1 port) 

N8143-111 

NOTE: 

 

Keyboard of N8143-105F/-106F does not have 10-key. 

9.2 

KVM Switch 

Category

 

Product Name / Description 

Part Number 

KVM Switch 

Server Switch Unit (8 server) 

1U USB 8 port KVM switch 

N8191-14F 

Cable 

KVM 

Switch Unit Connection Cable Set (USB,1.8m) 

1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(1A) 

 

 

Switch Unit Connection Cable Set (USB,3m) 

3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(03) 

 

 

Switch Unit Connection Cable Set (USB,5m) 

5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 

K410-118(05) 

 

Cascading 

Switch Unit Connection Cable 1.8 m 

1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 

K410-119(1A) 

NOTE: 

 

Order Switch Unit Connection Cable Set as same sets as servers to be connected to. (N8191-14F

  max 8 servers). 

9.3 

Server Management License 

Product Name / Description 

Part Number 

License for Remote Management (Advanced) 

License per server 
Remote console: 

N8115-33

 

Summary of Contents for Express5800/R110j-1

Page 1: ...de Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server January 25 2019 Revision 1 0 NEC Corporation ...

Page 2: ...oot Mode Setting 22 8 5 Management LAN with Serial kit 22 9 Add on Components 23 9 1 17 inch LCD Console Drawer 23 9 2 KVM Switch 23 9 3 Server Management License 23 9 4 Dust Proof Filter Kit 24 9 5 Starter Pack DVD 24 REFERENCES 25 External Views 25 Front and Rear Views 25 Dimensions mm 27 General Supplementary Matters 28 Memory Supplementary Matters 29 Internal drive supplementary matters 30 Con...

Page 3: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 3 REVISION HISTORY 39 ...

Page 4: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 4 Model Lineup 4x 2 5 inch Drive Model 2x 3 5 inch Drive Model ...

Page 5: ...Slots Standard Total 3 slots available 1 PCIe 3 0 x8 x8 connector or 1x FLOM 1 PCIe 3 0 x8 x16 connector 1 PCIe 3 0 x4 for a dedicated RAID card The slot mix changes by installing an optional riser card Video Controller VRAM Integrated in Server Management Controller 16MB Resolution 640x480 800x600 1 024x768 1 280x1 024 1 600x1 200 1 920x1 200 Interfaces Front 1x USB3 0 1x USB2 0 BMC Rear 2x USB3 ...

Page 6: ... Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 6 Configuration Diagram 4x 2 5 inch Drive Model Legend Standard Components Mandatory components 2x 3 5 inch Drive Model Legend Standard Components Mandatory components ...

Page 7: ... x4 for a dedicated RAID controller Riser Card Required N8116 90 Riser Card Kit 2xPCI Slot1 PCIe 3 0 x8 x8 connector Low Profile 168mm length Slot2 PCIe 3 0 x8 x16 connector Full height 168mm length N8116 89 Riser Card Kit 1xPCI FLOM Slot1 PCIe 3 0 x8 FLOM Slot2 PCIe 3 0 x8 x16 connector Full height 168mm length NOTE Minimum one riser card must be installed ...

Page 8: ...m G5400 Processor Kit Intel Pentium Gold Processor G5400 2C 4T 3 70GHz TDP54W 4MB N8101 1512 Core i3 8300 Processor Kit Intel Core Processor i3 8300 4C 4T 3 70GHz TDP62W 8MB N8101 1515 Xeon E 2124 Processor Kit Intel Xeon Processor E 2124 4C 4T 3 30GHz TDP71W 8MB N8101 1504 Xeon E 2134 Processor Kit Intel Xeon Processor E 2134 4C 8T 3 50GHz TDP71W 8MB N8101 1505 Xeon E 2144G Processor Kit Intel Xe...

Page 9: ...eed depends on CPU series Processor Type DIMM Speed Intel Xeon E 2124 Intel Xeon E 2126G Intel Xeon E 2134 Intel Xeon E 2136 Intel Xeon E 2144G Intel Xeon E 2174G Intel Xeon E 2186G 2666 MHz Intel Core i3 8300 Intel Pentium G5400 2400 MHz Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system Operating Systems Maximum Memory Size Supported...

Page 10: ...can be installed if the system install N8154 134 Internal DVD Drive Installation Kit 4 A RAID Controller N8103 192 193 is required when N8154 135 2x 2 5 inch Hot Plug Drive Cage Kit SAS SATA and N8118 312 M 2 SATA SSD installation kit are selected together Drive Bay for 2 5 inch Drive Model Four 2 5 inch drive bays are standard With an optional 2 5 inch drive cage up to six 2 5 inch drive bays can...

Page 11: ...al SAS SATA Cable SATA cable set for R110j 1 2x 3 5 inch Drive Model to RAID controller for dedicated PCI slot and R110j 1 to M 2 SATA SSD Installation Kit and K410 446 00 Note M 2 SATA SSD must be ordered with N8118 312 M 2 SATA SSD Installation kit and K410 446 00 Internal SAS SATA Cable K410 446 00 Internal SAS SATA Cable contains each cables for RAID controller for dedicated PCI slot and M 2 S...

Page 12: ... not supported in Embedded SATA Controller configuration M 2 SATA SSD Installation Kit N8118 312 and 2x 2 5 inch Hot Plug Drive Cage Kit SAS SATA N8154 135 can t be mixed in Embedded SATA Controller configuration Please chose RAID Controller for those configurations 4 3 3 2 5 inch Drive Model RAID Controller for Dedicated PCI Slot Choose RAID controller for suitable feature and performance RAID Co...

Page 13: ...for PCI Cards and Embedded Controllers All hard drives within a RAID array should be of the same capacity Embedded SATA RAID Controller configuration supports SATA HDD and SATA SSD only SAS HDD and SAS SSD does not supported in Embedded SATA Controller configuration 4 3 6 3 5 inch Drive Model RAID Controller for Dedicated PCI Slot Choose RAID controller for suitable feature and performance RAID Co...

Page 14: ...D 3 480GB Hot Plug 2 5 inch SATA SSD 1x 480GB SATA SSD 2 5 inch 6Gb s 512n sector Value Endurance N8150 1737 960GB Hot Plug 2 5 inch SATA SSD 1x 960GB SATA SSD 2 5 inch 6Gb s 512n sector Value Endurance N8150 1738 1 92TB Hot Plug 2 5 inch SATA SSD 1x 1 92TB SATA SSD 2 5 inch 6Gb s 512n sector Value Endurance N8150 1739 NOTE All drives within a RAID array should be of the same type capacity and end...

Page 15: ... SSD 1x 800GB SAS SSD 2 5 inch 12Gb s 512n sector Middle Endurance N8150 1751 Value Endurance DWPD 3 400GB Hot Plug 2 5 inch SAS SSD 1x 400GB SAS SSD 2 5 inch 12Gb s 512n sector Value Endurance N8150 1752 800GB Hot Plug 2 5 inch SAS SSD 1x 800GB SAS SSD 2 5 inch 12Gb s 512n sector Value Endurance N8150 1753 Read Intensive DWPD 1 960GB Hot Plug 2 5 inch SAS SSD 1x 960GB SAS SSD 2 5 inch 12Gb s 512n...

Page 16: ... 12TB 7 2K Hot Plug 3 5 inch SAS HDD 1x 12TB Near Line SAS HDD 3 5 inch 12Gb s 7 200 rpm 512e sector N8150 590 1 1 Those are make to order products NOTE All drives within a RAID array should be of the same type capacity and rotation speed Up to two kinds of drives selected from SAS 10K HDDs SAS 15K HDDs SATA HDDs SATA SSDs SAS SSDs can be mixed Near Line SAS HDD 7200 rpm and SAS HDD 10 000rpm 15 0...

Page 17: ... N8160 102 NOTE Internal DVD SuperMulti Drive is supported only on limited OS For more details please see OS Support Matrix for PCI Cards and Embedded Controllers Internal DVD Drive Installation Kit N8154 125 is mutually exclusive with N8154 135 2x2 5 inch Hot Plug Drive Cage Kit SAS SATA N8151 137 138 can be installed in 4x 2 5 inch Drive Model with N8154 134 or 2x 3 5 inch Drive Model If N8154 1...

Page 18: ...PCIe 3 0 x16 slot N8116 89 Network Interface Controller Category Product Name Description Part Number LOM Card FLOM Slot NOTE N8116 89 Riser Card Kit required 1GbE Quad Port 1000BASE T LOM Card Intel Ethernet Controller I350 PCIe 2 0 x4 N8104 172 10GbE Dual Port 10GBASE T LOM Card QLogic 57810S PCIe 2 0 x8 N8104 173 Adapter GbE Dual Port 1000BASE T Adapter Broadcom BCM5720 Gigabit Ethernet Control...

Page 19: ...r one team Windows Server 2016 Red Hat Enterprise Linux 7 5 later VMware ESXi 6 5 VMware ESXi 6 7 10GbE NIC N8104 183 Up to four ports per one team Windows Server 2016 Red Hat Enterprise Linux 7 5 later VMware ESXi 6 5 VMware ESXi 6 7 10GbE NIC N8104 185 Up to four ports per one team Windows Server 2016 Red Hat Enterprise Linux 7 5 later VMware ESXi 6 5 VMware ESXi 6 7 NOTE NIC Teaming feature is ...

Page 20: ...Storage T LTO DEU LTO autoldr ESXi 6 5u2 or later iStorage M ESXi 6 7 or later iStorage M Support Qualified N A LTO DEU Internal LTO drive on 1U Device Expansion Unit N8141 69F LTO autoldr LTO Autoloder LL009F T30A T60A NOTE iStorage T LTO drives doesn t support VMware ESXi For details such as OS support function etc please refer to NEC Storage website Quick reference support matrix shows compatib...

Page 21: ...uration Guide for supported SAS cable 8 Other Add in Components 8 1 Power Supply Category Product Name Description Part Number Non Redundant 290W Non hot Plug Power Supply NOTE This controller is a factory installation option No AC power cord is included N8181 179 Redundant Power Unit 500W Platinum Hot Plug Power Supply 1 x 500 Watt 80 PLUS Platinum including one 2m IEC320 C14 power cord N8181 159...

Page 22: ...luding 2x 8GB microSD USB dual microSD memory card reader RAID1 Support N8106 016 NOTE The USB Memory Kit is installed in the system when you order it with the base model The kit does not include VMware ESXi installation media and license 8 4 Boot Mode Setting The server supports Legacy mode and UEFI mode default as an OS Boot Mode See the table below for the Boot Mode and X2APIC setting for each ...

Page 23: ...5 pin mini D sub VGA cable 1 8 m N8143 108F 17 3inch LCD Console Drawer 1port 17 3 inch wide Full HD LCD US 103 keys Keyboard with 10 key Touch pad with 2 button 1U height 4 pin USB B to 4 pin USB A cable 1 8 m 15 pin mini D sub VGA cable 1 8 m DVI D cable 1 8m N8143 122F Keypad Keyboard Unit JP JP 108 keys Keyboard with 10 key for N8143 108F 17inch LCD Console Drawer 1 port N8143 109 Keyboard Uni...

Page 24: ... sets of dust proof filters N8147 32 NOTE The Dust Proof Filter Kit is make to order products Please consult your sales representative in regard to the production lead time 9 5 Starter Pack DVD The starter pack DVD includes the software and driver qualified by NEC In order to obtain technical support from NEC please be sure to install the software and drivers provided with the starter pack The lat...

Page 25: ...h Drive Bays F Health LED B 2 5 inch Drive Bays Optical Drive Bay Optional G LINK ACT LED C Pull out Tab H Power On standby button LED D Service port I UID button LED E USB 3 0 port 2x 3 5 Drive Model Front View Legend A 3 5 inch Drive Bays F Health LED B Optical Drive Bay Optional G LINK ACT LED C Pull out Tab H Power On standby button LED D Service port I UID button LED E USB 3 0 port ...

Page 26: ... January 2019 26 Rear View for Non redundant PSU Configuration Rear View for Redundant PSU Configuration Legend A PCI Slot Optional E 2x USB 3 0 port B Management LAN Connector Optional F UID LED C VGA Connector G Serial port Optional D NIC Connector H Power Supply Unit Optional ...

Page 27: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 27 Dimensions mm ...

Page 28: ...al not binary 1GB 1000 3B 1TB 1000 4B PCI expansion slot Transfer speed of PCI Express PCI Express PCIe 2 5Gb s simplex per lane PCI Express 2 0 PCIe 2 0 5Gb s simplex per lane PCI Express 3 0 PCIe 3 0 8Gb s simplex per lane Time display A system clock is affected by temperature conditions in storage If high accuracy of the system clock is required use of NTP servers is recommended ...

Page 29: ...performance efficiently in multiple cores and tasks operation Registered DIMM RDIMM can be installed up to 4 When installing DIMMs higher capacity memory must be installed preferentially if this rule is ignored it may cause failures of DIMMs This rule applies to the factory installation Memory population varies with number of installed DIMMs In installation of 1 or 3 DIMMs per CPU optimal performa...

Page 30: ...on RAID 1 6 Non Embedded RAID configuration RAID 0 1 10 1 RAID0 Single drive 2 RAID1 3 2 in RAID1 1 for hotspare 4 6 4 6 in RAID10 5 4 in RAID10 1 for a hotspare RAID controller configuration RAID 0 1 10 1 RAID0 Single drive 2 RAID1 3 2 in RAID1 1 for a hotspare 4 6 4 6 in RAID10 5 4 in RAID10 1 for a hotspare RAID controller configuration RAID 0 1 5 6 10 1 RAID0 Single drive 2 RAID1 3 6 RAID5 Con...

Page 31: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 31 See some examples as below ...

Page 32: ...le IRC Pre OS Only Global team collaboration for up to six consoles Integrated Remote Console IRC recording and playback Virtual Serial Port recording and playback Text based remote console via SSH Email alert Remote Syslog feature Advanced power management power history graph BMC federation management BMC detection for BMC federation Remote serial console Virtual Serial Port Server Health Summary...

Page 33: ...essor Kit N8101 1510 Xeon E 2136 Processor Kit N8101 1518 Xeon E 2186G Processor Kit N8102 718 8GB DDR4 2666 UNB Memory Kit N8102 719 16GB DDR4 2666 UNB Memory Kit N8154 135 2x2 5 inch Hot Plug Drive Cage Kit SAS SATA N8118 312 M 2 SATA SSD Installation kit K410 446 00 Internal SAS SATA Cable Embedded SATA non RAID Controller Embedded SATA RAID Controller N8103 192 RAID Controller RAID 0 1 N8103 1...

Page 34: ... 3 5 inch SATA HDD N8150 569 6TB 7 2K Hot Plug 3 5 inch SATA HDD N8150 570 8TB 7 2K Hot Plug 3 5 inch SATA HDD N8150 588 12TB 7 2K Hot Plug 3 5 inch SATA HDD N8150 573 8TB 7 2K Hot Plug 3 5 inch SAS HDD N8150 590 12TB 7 2K Hot Plug 3 5 inch SAS HDD N8150 1709 240GB Non Hot Plug M 2 SATA SSD N8150 1710 480GB Non Hot Plug M 2 SATA SSD N8154 134 Internal DVD Drive Installation Kit K410 445 00 Interna...

Page 35: ...ler 2ch N8190 171 Fibre Channel Controller 1ch N8190 172 Fibre Channel Controller 2ch N8103 197 SAS Controller N8103 E184 SAS Controller N8103 184 SAS Controller N8181 179 290W Non hot Plug Power Supply N8181 159 500W Hot Plug Power Supply N8181 180 Redundant PSU Cage N8115 35 Trusted Platform Module Kit N8106 017 8GB USB Memory N8106 016 Dual 8GB microSD Kit USB N8117 12 Management Lan with Seria...

Page 36: ...Up to two RAID card with cache N8103 193 196 can be installed Need one Battery Backup Unit N8103 215 per server N8103 197 N8190 165 N8190 166 N8190 167 N8190 171 N8190 172 N8190 163 N8190 164 N8104 185 N8104 182 N8104 183 N8118 312 N8104 178 N8104 180 Low N8104 181 Up to one FC 2ch card N8190 164 172 can be installed on 4 thread CPU system 5 priority of factory mounted Part Number Product Name Sup...

Page 37: ...e capacity 2 5 TB N8151 142 Internal LTO SAS LTO7 Half height Native capacity 6 TB N8151 143 RDX Internal RDX USB N8151 139 Boot Mode Setting The server supports Legacy mode and UEFI mode default as an OS Boot Mode See the table below for the Boot Mode and X2APIC setting for each Operating System As the default settings at the factory UEFI mode is set as OS Boot mode and X2APIC is enabled Refer to...

Page 38: ...es Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for te...

Page 39: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 R110j 1 NEC Corporation Revision 1 0 January 2019 39 Revision History Revision Date Description 1 0 January 25 2018 Initial release ...

Reviews: